Efficacy and Safety of Different Energy Settings for Atrial Fibrillation Ablation using the Duty-cycled Radiofrequency Ablation Catheter (PVAC)

Stefan Lönnerholm, Helena Malmborg, Per Blomström, Carina Blomström-Lundqvist

Journal of Cardiovascular Medicine and Cardiology · 2014

DOI: 10.17352/2455-2976.000002 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Cardiovascular Medicine and Cardiology, 2014. Verfasst von Stefan Lönnerholm und 3 weiteren Autor:innen. Die Arbeit nennt 13 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In recent years, new ablation catheters have been developed to facilitate atrial fibrillation (AF) ablation procedures, including the multi-electrode pulmonary vein ablation catheter (PVAC), capable of using different proportions of unipolar and bipolar energy. The purpose of this study was to evaluate the acute efficacy, as well as safety, when using the two different energy settings for the PVAC catheter. Methods and Results: Thirty-five patients with a mean age of 62 ± 7.7 years with paroxysmal (54%) or persistent AF were included in the study and randomized to 4:1 versus 2:1 bipolar/unipolar energy setting with the PVAC device. The mean number of applications with the PVAC catheter was 41 ± 10 and 51 ± 15 (p = 0.3) respectively with the 4:1 and the 2:1 setting. Touch-up with another RF ablation catheter was necessary in 3 and 7 patients respectively in the 4:1 and 2:1 group. The procedure time was 155 ± 35 and 174 ± 41minutes respectively and the total fluoroscopy time, including the time for touch-up with another catheter, was 42 ± 14 and 50 ± 17 minutes respectively with the 4:1 versus 2:1 setting. No complications were seen in any group. Conclusion: There was no significant difference between the 4:1 and 2:1 bipolar-to-unipolar energy setting with the PVAC regarding the number of applications needed to create (PVI), the number of patients in which (PVI) could be achieved without touch-up applications, the procedure time or the fluoroscopy time.

Zitieren

APA

Lönnerholm, S., Malmborg, H., Blomström, P., & Blomström-Lundqvist, C. (2014). Efficacy and Safety of Different Energy Settings for Atrial Fibrillation Ablation using the Duty-cycled Radiofrequency Ablation Catheter (PVAC). Journal of Cardiovascular Medicine and Cardiology. https://doi.org/10.17352/2455-2976.000002

Vancouver

Lönnerholm S, Malmborg H, Blomström P, Blomström-Lundqvist C. Efficacy and Safety of Different Energy Settings for Atrial Fibrillation Ablation using the Duty-cycled Radiofrequency Ablation Catheter (PVAC). Journal of Cardiovascular Medicine and Cardiology. 2014. doi:10.17352/2455-2976.000002

BibTeX
@article{Lnnerholm2014,
  author = {Lönnerholm, Stefan and Malmborg, Helena and Blomström, Per and Blomström-Lundqvist, Carina},
  title = {Efficacy and Safety of Different Energy Settings for Atrial Fibrillation Ablation using the Duty-cycled Radiofrequency Ablation Catheter (PVAC)},
  journal = {Journal of Cardiovascular Medicine and Cardiology},
  year = {2014},
  doi = {10.17352/2455-2976.000002}
}
Kostenlos starten →