EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Evaluation of operation control parameters of a residential solar organic Rankine cycle with effects of expander-generator coupling

Cagri Kutlu, Mehmet Tahir Erdinc, Amin Ehtiwesh, Michele Bottarelli, Yuehong Su, Saffa Riffat

Global Decarbonisation · 03.06.2025 · 1 · 1-19

DOI: 10.17184/eac.9437 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Global Decarbonisation, online erschienen am 03.06.2025. Verfasst von Cagri Kutlu und 5 weiteren Autor:innen. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Solar-powered organic Rankine cycles (s-ORCs) are promising technologies for converting solar radiation into electrical energy, offering a viable alternative to conventional photovoltaics. However, the intermittent nature of solar radiation presents operational challenges, as these systems cannot regulate their heat input and rely entirely on solar energy availability. This study investigates the transient performance of a small-scale s-ORC system without thermal energy storage, focusing on how operational parameters influence system behaviour under variable solar conditions. A simulation model is developed, integrating effectiveness–NTU-based heat exchanger models and a validated expander–generator coupling sub-model that accounts for real-world responses such as torque balance, rotational speed, and internal leakage. Key control parameters, including the flow rates of the refrigerant, cooling water, and thermal oil, are examined to assess their influence on overall performance. The results show that solar heat input is the dominant factor affecting system efficiency, followed by the cooling water flow rate, which has a more significant impact than thermal oil flow. Based on a one-day simulation, the expander’s volumetric efficiency was found to average around 60% due to leakage losses, and the expander predominantly operated under off-design conditions. The generator efficiency varied between 49% and 58%, with lower rotational speeds resulting in better conversion efficiency.

Zitieren

APA

Kutlu, C., Erdinc, M. T., Ehtiwesh, A., Bottarelli, M., Su, Y., & Riffat, S. (2025). Evaluation of operation control parameters of a residential solar organic Rankine cycle with effects of expander-generator coupling. Global Decarbonisation, 1, 1-19. https://doi.org/10.17184/eac.9437

Vancouver

Kutlu C, Erdinc MT, Ehtiwesh A, Bottarelli M, Su Y, Riffat S. Evaluation of operation control parameters of a residential solar organic Rankine cycle with effects of expander-generator coupling. Global Decarbonisation. 2025;1:1-19. doi:10.17184/eac.9437

BibTeX
@article{Kutlu2025,
  author = {Kutlu, Cagri and Erdinc, Mehmet Tahir and Ehtiwesh, Amin and Bottarelli, Michele and Su, Yuehong and Riffat, Saffa},
  title = {Evaluation of operation control parameters of a residential solar organic Rankine cycle with effects of expander-generator coupling},
  journal = {Global Decarbonisation},
  year = {2025},
  volume = {1},
  pages = {1--19},
  doi = {10.17184/eac.9437}
}
Kostenlos starten →