Subcutaneous microfuse-activated device for programmed pulsatile drug delivery
Bio-Design and Manufacturing · 2026-05 · 9 (3) · 599-611
DOI: 10.1631/bdm.2500511 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bio-Design and Manufacturing, online erschienen am 28.04.2026. Verfasst von Myoung Ju Kim und 12 weiteren Autor:innen. Die Arbeit nennt 73 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Pulsatile drug delivery, in which rapid drug release is separated by defined lag periods, offers significant therapeutic advantages but is limited by the need for repeated injections and poor patient adherence. Here, we introduce the fused device (FUSED), a subcutaneous system enabling programmed multidose drug delivery through a single implantation. FUSED comprises paired delay and shot units that regulate dosing intervals and trigger pulsatile drug release, respectively. After implantation, body fluids gradually dissolve the microfuse in each delay unit, with the delay duration determined by fuse length. Once fluid reaches a shot unit, an effervescent reaction is initiated, producing rapid drug release. In vitro and in vivo evaluations demonstrated precise pulsatile release of the model antigen ovalbumin, effectively reproducing prime–boost vaccination timing and eliciting the corresponding immune response. These results suggest that FUSED may provide a viable alternative to repeated injections and improve adherence in multidose therapeutic regimens.
Zitieren
APA
Kim, M. J., Ji, H. B., Cho, Y. C., Cho, J. C., Kim, W. H., Park, G. M., Min, C. H., Kim, M. J., Kim, C. R., Han, J. H., Lee, C., Prausnitz, M. R., & Choy, Y. B. (2026). Subcutaneous microfuse-activated device for programmed pulsatile drug delivery. Bio-Design and Manufacturing, 9(3), 599-611. https://doi.org/10.1631/bdm.2500511
Vancouver
Kim MJ, Ji HB, Cho YC, Cho JC, Kim WH, Park GM, et al. Subcutaneous microfuse-activated device for programmed pulsatile drug delivery. Bio-Design and Manufacturing. 2026;9(3):599-611. doi:10.1631/bdm.2500511
BibTeX
@article{Kim2026,
author = {Kim, Myoung Ju and Ji, Han Bi and Cho, Yong Chan and Cho, Jae Chan and Kim, Woo Hyun and Park, Gi Min and Min, Chang Hee and Kim, Min Ji and Kim, Cho Rim and Han, Jae Hoon and Lee, Cheol and Prausnitz, Mark R. and Choy, Young Bin},
title = {Subcutaneous microfuse-activated device for programmed pulsatile drug delivery},
journal = {Bio-Design and Manufacturing},
year = {2026},
volume = {9},
number = {3},
pages = {599--611},
doi = {10.1631/bdm.2500511}
}
EUVIMED