Improvement of Imaging Conditions to Improve the Detection Rate of Head and Neck Cancer by Positron Emission Tomography/Computed Tomography Examination
The Tohoku Journal of Experimental Medicine · 2023
DOI: 10.1620/tjem.2023.j026 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Tohoku Journal of Experimental Medicine, 2023. Verfasst von Hayato Odagiri und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic Image Analysis, Tohoku University Graduate School of Medicine. Hauptthemen laut MEDLINE: Positron Emission Tomography Computed Tomography, Head and Neck Neoplasms. Die Arbeit nennt 21 Literaturangaben.
Abstract (Originalsprache)
Positron emission tomography (PET)/computed tomography (CT) has improved sensitivity and resolution using silicon photomultiplier as a photosensor. Previously, only a fixed setting was available for the shooting time of 1 bed, but now, the shooting time can be changed for each bed. Time can be shortened or extended depending on the target area. A few studies reported on image reconstruction conditions for head and neck cancer in whole-body PET/CT examinations. Thus, this study aimed to optimize the imaging conditions of the head and neck region during whole-body imaging. A cylindrical acrylic container with a 200 mm diameter was used to simulate the head and neck area using a PET/CT system equipped with a semiconductor detector. Spheres of 6-30 mm in diameter were enclosed in the 200 mm diameter cylindrical acrylic vessel. Radioactivity in 18F solution (Hot:BG ratio 4:1) was enclosed in a phantom following the Japanese Society of Nuclear Medicine (JSNM) guidelines. Background radioactivity concentration was 2.53 kBq/mL. List mode acquisition of 1,800 s was collected at 60-1,800 s with the field of view of 700 mm and 350 mm. The image was reconstructed by resizing the matrix to 128 × 128, 192 × 192, 256 × 256, and 384 × 384, respectively. The imaging time per bed in the head and neck should be at least 180 s, and the reconstruction conditions should be a field of view (FOV) of 350 mm, matrix sizes of ≥ 192, and a Bayesian penalized likelihood (BPL) reconstruction with a β-value of 200. This allows detection of > 70% of the 8-mm spheres in the images.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Diagnostic Image Analysis, Tohoku University Graduate School of Medicine.
- Department of Diagnostic Radiology, Tohoku University Hospital.
- Department of Oral and Maxillofacial Radiology, Tohoku University Hospital.
- Department of Radiology, Tohoku University Hospital.
Zitieren
APA
Odagiri, H., Takanami, K., Kaneta, T., Usui, A., Kojima, I., Kodama, H., Saitou, S., Tanaka, Y., Dendo, Y., & Takase, K. (2023). Improvement of Imaging Conditions to Improve the Detection Rate of Head and Neck Cancer by Positron Emission Tomography/Computed Tomography Examination. The Tohoku Journal of Experimental Medicine. https://doi.org/10.1620/tjem.2023.j026
Vancouver
Odagiri H, Takanami K, Kaneta T, Usui A, Kojima I, Kodama H, et al. Improvement of Imaging Conditions to Improve the Detection Rate of Head and Neck Cancer by Positron Emission Tomography/Computed Tomography Examination. The Tohoku Journal of Experimental Medicine. 2023. doi:10.1620/tjem.2023.j026
BibTeX
@article{Odagiri2023,
author = {Odagiri, Hayato and Takanami, Kentaro and Kaneta, Tomohiro and Usui, Akihito and Kojima, Ikuho and Kodama, Hiroyasu and Saitou, Shin and Tanaka, Yoshitaka and Dendo, Yutaka and Takase, Kei},
title = {Improvement of Imaging Conditions to Improve the Detection Rate of Head and Neck Cancer by Positron Emission Tomography/Computed Tomography Examination},
journal = {The Tohoku Journal of Experimental Medicine},
year = {2023},
doi = {10.1620/tjem.2023.j026}
}
EUVIMED