EUVIMEDEUVIMED entdecken
Crossref

How Does Rigid Registration Affect Fixed-Coordinate Pixel-Anomaly Persistence in Breast Ultrasound?

Dikshya Karki, Meng Xu, Kuan Huang, Yingfeng Wang

Proceedings of the AAAI Symposium Series · 06.11.2026 · 10 (1) · 1203-1208

DOI: 10.1609/aaaiss.v10i1.43545 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Proceedings of the AAAI Symposium Series, online erschienen am 06.11.2026. Verfasst von Dikshya Karki und 3 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rigid registration aligns ultrasound frames according to anatomical content, but image-grid-fixed anomalies do not necessarily preserve the same raster coordinate after transformation. We investigate this coordinate-persistence question using paired frames from the Breast Ultrasound Video dataset. A persistent stuck-at-zero perturbation was simulated by setting the same raster coordinate to zero in both frames, after which a two-dimensional rigid transform was independently estimated for each modified pair and the later frame was resampled into the coordinate system of the earlier frame. We measured post-registration zero presence at the original coordinate and within progressively larger neighborhoods across four centered spatial regions. The exact-coordinate analysis asks whether a coordinate forced to zero in both raw frames remains zero at that same raster location after registration; it does not attempt identity-aware recovery of the injected pixel. Exact-coordinate zero presence was 3.57% overall, meaning that the original coordinate was nonzero in 96.43% of trials. Zero presence increased to 32.73% within an 11x11 neighborhood; these wider-window results are interpreted descriptively because nearby zeros may arise from other image content or resampling. The findings show that exact same-coordinate zero persistence is uncommon under the evaluated rigid-registration pipeline, motivating further study of image-grid artifacts in ultrasound quality control and trustworthy medical AI.

Zitieren

APA

Karki, D., Xu, M., Huang, K., & Wang, Y. (2026). How Does Rigid Registration Affect Fixed-Coordinate Pixel-Anomaly Persistence in Breast Ultrasound?. Proceedings of the AAAI Symposium Series, 10(1), 1203-1208. https://doi.org/10.1609/aaaiss.v10i1.43545

Vancouver

Karki D, Xu M, Huang K, Wang Y. How Does Rigid Registration Affect Fixed-Coordinate Pixel-Anomaly Persistence in Breast Ultrasound?. Proceedings of the AAAI Symposium Series. 2026;10(1):1203-1208. doi:10.1609/aaaiss.v10i1.43545

BibTeX
@article{Karki2026,
  author = {Karki, Dikshya and Xu, Meng and Huang, Kuan and Wang, Yingfeng},
  title = {How Does Rigid Registration Affect Fixed-Coordinate Pixel-Anomaly Persistence in Breast Ultrasound?},
  journal = {Proceedings of the AAAI Symposium Series},
  year = {2026},
  volume = {10},
  number = {1},
  pages = {1203--1208},
  doi = {10.1609/aaaiss.v10i1.43545}
}
Kostenlos starten →