EUVIMEDEUVIMED entdecken
Crossref

Organ-Aware Routing Mixture-of-Retrieval Augmented Generation for Fetal Ultrasound Reporting

Bin Pu, Siyu Wang, Rongbin Li, Xinpeng Ding, Lei Zhao, Chaoqi Chen, Shengli Li, Kenli Li

Proceedings of the AAAI Conference on Artificial Intelligence · 14.03.2026 · 40 (10) · 8448-8456

DOI: 10.1609/aaai.v40i10.37795 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Proceedings of the AAAI Conference on Artificial Intelligence, online erschienen am 14.03.2026. Verfasst von Bin Pu und 7 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Fetal ultrasound screening is a uniquely complex diagnostic task involving the simultaneous assessment of multiple fetal organs—each with its own anatomical and clinical context—within a single examination. Automating report generation for such cases poses a significant challenge: unlike existing methods that focus on single-organ radiology tasks (e.g., chest X-rays), fetal ultrasound requires reasoning over a structured, multiple-to-multiple setting, i.e., multi-organ images corresponding to a multi-section report. In this paper, we introduce FetusR, the first large-scale dataset for multi-organ fetal ultrasound reporting, containing 15,594 real-world cases with rich organ-wise annotations. To address the intrinsic image-report alignment, we propose Organ-Aware Routing Mixture-of-Retrieval Augmented Generation (ORM-RAG) inspired by the Mixture-of-Experts paradigm. Our method decomposes the complex alignment problem into multiple one-to-one sub-retrieval tasks. Specifically, ORM-RAG integrates (1) an organ-aware mixture-of-retrieval module that partitions the retrieval space into organ-specific corpora for independent retrieval, and (2) a dynamic routing mechanism that selectively aggregates high-confidence organ-specific reports while filtering uncertain ones. Extensive experiments demonstrate that our method significantly outperforms state-of-the-art baselines across both textual similarity and clinical accuracy metrics. Our work opens a new direction for long-form, structured report generation in real-world, multi-organ medical imaging scenarios.

Zitieren

APA

Pu, B., Wang, S., Li, R., Ding, X., Zhao, L., Chen, C., Li, S., & Li, K. (2026). Organ-Aware Routing Mixture-of-Retrieval Augmented Generation for Fetal Ultrasound Reporting. Proceedings of the AAAI Conference on Artificial Intelligence, 40(10), 8448-8456. https://doi.org/10.1609/aaai.v40i10.37795

Vancouver

Pu B, Wang S, Li R, Ding X, Zhao L, Chen C, et al. Organ-Aware Routing Mixture-of-Retrieval Augmented Generation for Fetal Ultrasound Reporting. Proceedings of the AAAI Conference on Artificial Intelligence. 2026;40(10):8448-8456. doi:10.1609/aaai.v40i10.37795

BibTeX
@article{Pu2026,
  author = {Pu, Bin and Wang, Siyu and Li, Rongbin and Ding, Xinpeng and Zhao, Lei and Chen, Chaoqi and Li, Shengli and Li, Kenli},
  title = {Organ-Aware Routing Mixture-of-Retrieval Augmented Generation for Fetal Ultrasound Reporting},
  journal = {Proceedings of the AAAI Conference on Artificial Intelligence},
  year = {2026},
  volume = {40},
  number = {10},
  pages = {8448--8456},
  doi = {10.1609/aaai.v40i10.37795}
}
Kostenlos starten →