Objective

To compare image quality between deep learning image reconstruction (DLIR) low-dose chest CT and iterative reconstruction (ASIR-V) standard-dose chest CT in patients with chronic obstructive pulmonary disease (COPD).

Methods

A total of 106 patients were prospectively enrolled and underwent standard-dose (SD) and low-dose (LD) chest CT scans. The LD scans were reconstructed using ASIR-V (LD-AR) and three DLIR strength levels (LD-DL/DM/DH), whereas the SD scans were reconstructed using ASIR-V (SD-AR). Noise (standard deviation), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) of the anatomical structures were measured or calculated. The subjective image quality was scored by radiologists.

Results

Effective radiation dose was (4.0±1.37) mSv for the SD group and (1.14±0.47) mSv for the LD group. The LD-DLIR images exhibited lower noise, higher SNR, and higher CNR than the SD-AR images, with the LD-DH performing the best. Subjective scores indicated superior noise levels, anatomical clarity, and emphysema visualization in LD-DLIR images compared to SD-AR, with LD-DH receiving the highest score.

Conclusion

DLIR significantly improved chest CT image quality in patients with COPD while reducing the radiation dose by 71.5%, with DLIR-H providing optimal performance.

Schlagwörter

deep learning image reconstructionradiation dosechronic obstructive pulmonary diseaseimage qualityiterative reconstruction

Zitieren

APA

ZHANG, X., XUE, L., TANG, B., LIN, Q., YE, X., ZHENG, W., LIN, X., XIANG, L., & LIU, Y. (2026). Application Value of Deep Learning Reconstruction in Low-dose Chest CT for COPD. CT Lilun yu yingyong yanjiu, 35(1), 94-101. https://doi.org/10.15953/j.ctta.2025.265

Vancouver

ZHANG X, XUE L, TANG B, LIN Q, YE X, ZHENG W, et al. Application Value of Deep Learning Reconstruction in Low-dose Chest CT for COPD. CT Lilun yu yingyong yanjiu. 2026;35(1):94-101. doi:10.15953/j.ctta.2025.265

BibTeX
@article{ZHANG2026,
  author = {ZHANG, Xiaoyong and XUE, Liwei and TANG, Borong and LIN, Qiong and YE, Xiongxin and ZHENG, Wanyi and LIN, Xiaojuan and XIANG, Ling and LIU, Yuanfen},
  title = {Application Value of Deep Learning Reconstruction in Low-dose Chest CT for COPD},
  journal = {CT Lilun yu yingyong yanjiu},
  year = {2026},
  volume = {35},
  number = {1},
  pages = {94--101},
  doi = {10.15953/j.ctta.2025.265}
}
Kostenlos starten →