EUVIMEDEUVIMED entdecken
Crossref

Contrast Study of Low Tube Current Combined with Deep Learning Algorithms in Paranasal Sinus CT Imaging

Yufei SUN, Zhaohui ZHONG, Xiangming LI, Wanbo ZHOU, Chensi XU, Miao DENG, Lixin ZHANG

CT Lilun yu yingyong yanjiu · 2025-05 · 34 (3) · 351-358

DOI: 10.15953/j.ctta.2024.288 ↗

Kurz gefasst

Fachartikel in der Zeitschrift CT Lilun yu yingyong yanjiu, 2025-05. Verfasst von Yufei SUN und 6 weiteren Autor:innen.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To explore the application effect of a low tube current combined with a deep learning algorithm in paranasal sinus computed tomography (CT) imaging and to evaluate its advantages in terms of image quality and radiation dose.

Methods

Patients who underwent paranasal sinus CT examinations at Beijing Friendship Hospital, Capital Medical University, between March and November 2024 were retrospectively collected and divided into three groups: conventional dose group, low tube current with deep clearInfinity (CI) group, and clearView (CV) group. The CT values, SD values, signal-to-noise ratios (SNR), and contrast-to-noise ratios (CNR) of the inferior turbinate mucosa, medial pterygoid muscle, and temporal fossa fat were measured and calculated for each group to objectively assess image quality. In addition, two head and neck radiologists subjectively scored the image quality of the thinnest slice on a 4-point scale. The radiation doses in the conventional and low tube current groups were also compared.

Results

A total of 80 patients were included in this study, with 40 in each group. There were no statistically significant differences in the CT values among the three groups for the inferior turbinate mucosa, medial pterygoid muscle, and temporal fossa fat. There were no statistically significant differences in SD values, SNR, and CNR between the conventional-dose and CI groups. However, statistically significant differences were observed in SD values and SNR between the conventional and CV groups, as well as between the CI and CV groups for the inferior turbinate mucosa, medial pterygoid muscle, and temporal fossa fat. For CNR, statistically significant differences were also found between the conventional and CV groups and between the CI and CV groups in the inferior turbinate mucosa and medial pterygoid muscle regions. In terms of subjective image quality scores, the conventional and CI groups scored 3.93±0.26 and 3.88±0.33, respectively, which were significantly higher than the CV group’s score of 2.70±0.46. Additionally, the radiation dose in the low tube current group was reduced by approximately 74.8% compared to that in the conventional group, with a statistically significant difference.

Conclusion

Low tube current combined with a deep learning algorithmin paranasal sinus CT imaging can significantly reduce the radiation dose while maintaining image quality.

Schlagwörter

deep learning algorithmiterative algorithmparanasal sinus ctlow-dose ct

Zitieren

APA

SUN, Y., ZHONG, Z., LI, X., ZHOU, W., XU, C., DENG, M., & ZHANG, L. (2025). Contrast Study of Low Tube Current Combined with Deep Learning Algorithms in Paranasal Sinus CT Imaging. CT Lilun yu yingyong yanjiu, 34(3), 351-358. https://doi.org/10.15953/j.ctta.2024.288

Vancouver

SUN Y, ZHONG Z, LI X, ZHOU W, XU C, DENG M, et al. Contrast Study of Low Tube Current Combined with Deep Learning Algorithms in Paranasal Sinus CT Imaging. CT Lilun yu yingyong yanjiu. 2025;34(3):351-358. doi:10.15953/j.ctta.2024.288

BibTeX
@article{SUN2025,
  author = {SUN, Yufei and ZHONG, Zhaohui and LI, Xiangming and ZHOU, Wanbo and XU, Chensi and DENG, Miao and ZHANG, Lixin},
  title = {Contrast Study of Low Tube Current Combined with Deep Learning Algorithms in Paranasal Sinus CT Imaging},
  journal = {CT Lilun yu yingyong yanjiu},
  year = {2025},
  volume = {34},
  number = {3},
  pages = {351--358},
  doi = {10.15953/j.ctta.2024.288}
}
Kostenlos starten →