Application of a Contrast Enhancement Boost Technique in Cranial Four-dimensional Computed Tomography Angiography

Fang GAO, Yan ZHANG, Zhe LIU, Gaosheng ZHANG, Min XU, Ying ZHENG, Jian LI

CT Lilun yu yingyong yanjiu · 2025-11 · 34 (6) · 1142-1149

DOI: 10.15953/j.ctta.2024.122 ↗

Kurz gefasst

Fachartikel in der Zeitschrift CT Lilun yu yingyong yanjiu, 2025-11. Verfasst von Fang GAO und 6 weiteren Autor:innen.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective:This study aimed to explore the efficacy and versatility of contrast enhancement boost (CE-Boost) technology for enhancing blood vessels with varying phases and degrees of enhancement on cranial four-dimensional computed tomography angiography (4D-CTA). Methods: Forty-three patients who underwent cerebral CT perfusion (CTP) were enrolled retrospectively. For each patient, three single-phase images were selected from the 4D-CTA based on subjective scoring criteria: one image was scored as arterial early phase non-diagnostic (insufficient enhancement for clinical diagnosis), and two images were scored as arterial phase diagnostic (sufficient enhancement for clinical diagnosis). Subsequently, the corresponding CE-Boost group images were generated using subtraction software. Measurements were obtained on the normal side in six image groups, including: the middle cerebral artery (MCA) M1 segment, basilar artery (BA), and brainstem (BS). Objective image quality was assessed using the CT value, image noise, signal-to-noise ratio (SNR), and contrast noise ratio (CNR). The subjective image quality was assessed using a five-point Likert scale. Results:The CT attenuation value, noise value, SNR, and CNR of the MCA and BA were significantly higher in the CE-Boost group than in the original images. The subjective score of the CE-Boost group was higher than that of the original image (3.59±1.33 vs. 2.92±0.95). Conclusion:The CE-Boost technique can improve the objective image quality of arterial phase diagnostic images of intracranial 4D-CTA while improving the visualization of branch vessels. However, arterial early phase non-diagnostic images only improve the objective evaluation of the trunk and have limited ability to improve the visualization of intracranial branch vessels. This study suggests that the CE-Boost technique is suitable for arterial phase diagnostic images with an intracranial subjective score greater than or equal to 3.

Schlagwörter

x-ray computerangiographycontrast enhancement

Zitieren

APA

GAO, F., ZHANG, Y., LIU, Z., ZHANG, G., XU, M., ZHENG, Y., & LI, J. (2025). Application of a Contrast Enhancement Boost Technique in Cranial Four-dimensional Computed Tomography Angiography. CT Lilun yu yingyong yanjiu, 34(6), 1142-1149. https://doi.org/10.15953/j.ctta.2024.122

Vancouver

GAO F, ZHANG Y, LIU Z, ZHANG G, XU M, ZHENG Y, et al. Application of a Contrast Enhancement Boost Technique in Cranial Four-dimensional Computed Tomography Angiography. CT Lilun yu yingyong yanjiu. 2025;34(6):1142-1149. doi:10.15953/j.ctta.2024.122

BibTeX
@article{GAO2025,
  author = {GAO, Fang and ZHANG, Yan and LIU, Zhe and ZHANG, Gaosheng and XU, Min and ZHENG, Ying and LI, Jian},
  title = {Application of a Contrast Enhancement Boost Technique in Cranial Four-dimensional Computed Tomography Angiography},
  journal = {CT Lilun yu yingyong yanjiu},
  year = {2025},
  volume = {34},
  number = {6},
  pages = {1142--1149},
  doi = {10.15953/j.ctta.2024.122}
}
Kostenlos starten →