Evaluation of Rapid Colorimetric Lateral Flow Sensor for Hypoxia-Inducible Factor-1 Alpha Detection in High Altitude
Journal of Aerospace Technology and Management · 2026 · 18
DOI: 10.1590/jatm.v18.1432 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Aerospace Technology and Management, 2026. Verfasst von Shazreen Shaharuddin und 7 weiteren Autor:innen. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fundamental Research Grant Scheme – Early Career, Asian Office of Aerospace Research and Development.
Abstract (Originalsprache)
Hypoxia is a critical physiological risk in high-altitude aviation and aerospace environments, where early detection is essential to prevent cognitive impairment and loss of consciousness among aircrew. Hypoxia-inducible factor-1 alpha (HIF-1α) is a molecular biomarker that is rapidly upregulated under low-oxygen conditions. This study aimed to develop and evaluate a rapid, non-invasive lateral flow immunoassay (LFIA) for colorimetric detection of salivary HIF-1α. A total of 24 saliva samples were collected from participants at the Institute of Aviation Medicine and divided into two groups: sea level (control) and simulated altitude exposure at 10,000 feet. Salivary HIF-1α was detected using the developed LFIA sensor, while peripheral oxygen saturation (SpO₂) was concurrently measured using fingertip pulse oximetry to confirm hypoxic status. All participants tested negative for HIF-1α at sea level, whereas positive LFIA results were observed in all participants after altitude exposure, indicating 100% sensitivity under the study conditions. Mean SpO₂ decreased significantly from 98.1% at sea level to 90.8% at 10,000 feet. The LFIA produced rapid, visually interpretable results within minutes. The LFIA demonstrated high sensitivity and specificity for detecting hypoxia-induced HIF-1α in saliva, potentially as a rapid point-of-care tool for hypoxia monitoring in aviation and extreme environments.
Förderung
- Fundamental Research Grant Scheme – Early Career
- Asian Office of Aerospace Research and Development
Zitieren
APA
Shaharuddin, S., Miskan, M., Hassan, H. A., Mohd, S., Hashim, R., Mohammad, Z., Nordin, M. K. N., & Zainal, N. S. (2026). Evaluation of Rapid Colorimetric Lateral Flow Sensor for Hypoxia-Inducible Factor-1 Alpha Detection in High Altitude. Journal of Aerospace Technology and Management, 18. https://doi.org/10.1590/jatm.v18.1432
Vancouver
Shaharuddin S, Miskan M, Hassan HA, Mohd S, Hashim R, Mohammad Z, et al. Evaluation of Rapid Colorimetric Lateral Flow Sensor for Hypoxia-Inducible Factor-1 Alpha Detection in High Altitude. Journal of Aerospace Technology and Management. 2026;18. doi:10.1590/jatm.v18.1432
BibTeX
@article{Shaharuddin2026,
author = {Shaharuddin, Shazreen and Miskan, Maizatullifah and Hassan, Hasliza Abu and Mohd, Shaharuddin and Hashim, Rosnani and Mohammad, Zulkefley and Nordin, Mohd Khairul Nizam and Zainal, Noor Saadiah},
title = {Evaluation of Rapid Colorimetric Lateral Flow Sensor for Hypoxia-Inducible Factor-1 Alpha Detection in High Altitude},
journal = {Journal of Aerospace Technology and Management},
year = {2026},
volume = {18},
doi = {10.1590/jatm.v18.1432}
}
EUVIMED