EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Evaluation of Rapid Colorimetric Lateral Flow Sensor for Hypoxia-Inducible Factor-1 Alpha Detection in High Altitude

Shazreen Shaharuddin, Maizatullifah Miskan, Hasliza Abu Hassan, Shaharuddin Mohd, Rosnani Hashim, Zulkefley Mohammad, Mohd Khairul Nizam Nordin, Noor Saadiah Zainal

Journal of Aerospace Technology and Management · 2026 · 18

DOI: 10.1590/jatm.v18.1432 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Aerospace Technology and Management, 2026. Verfasst von Shazreen Shaharuddin und 7 weiteren Autor:innen. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fundamental Research Grant Scheme – Early Career, Asian Office of Aerospace Research and Development.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Hypoxia is a critical physiological risk in high-altitude aviation and aerospace environments, where early detection is essential to prevent cognitive impairment and loss of consciousness among aircrew. Hypoxia-inducible factor-1 alpha (HIF-1α) is a molecular biomarker that is rapidly upregulated under low-oxygen conditions. This study aimed to develop and evaluate a rapid, non-invasive lateral flow immunoassay (LFIA) for colorimetric detection of salivary HIF-1α. A total of 24 saliva samples were collected from participants at the Institute of Aviation Medicine and divided into two groups: sea level (control) and simulated altitude exposure at 10,000 feet. Salivary HIF-1α was detected using the developed LFIA sensor, while peripheral oxygen saturation (SpO₂) was concurrently measured using fingertip pulse oximetry to confirm hypoxic status. All participants tested negative for HIF-1α at sea level, whereas positive LFIA results were observed in all participants after altitude exposure, indicating 100% sensitivity under the study conditions. Mean SpO₂ decreased significantly from 98.1% at sea level to 90.8% at 10,000 feet. The LFIA produced rapid, visually interpretable results within minutes. The LFIA demonstrated high sensitivity and specificity for detecting hypoxia-induced HIF-1α in saliva, potentially as a rapid point-of-care tool for hypoxia monitoring in aviation and extreme environments.

Förderung

  • Fundamental Research Grant Scheme – Early Career
  • Asian Office of Aerospace Research and Development

Zitieren

APA

Shaharuddin, S., Miskan, M., Hassan, H. A., Mohd, S., Hashim, R., Mohammad, Z., Nordin, M. K. N., & Zainal, N. S. (2026). Evaluation of Rapid Colorimetric Lateral Flow Sensor for Hypoxia-Inducible Factor-1 Alpha Detection in High Altitude. Journal of Aerospace Technology and Management, 18. https://doi.org/10.1590/jatm.v18.1432

Vancouver

Shaharuddin S, Miskan M, Hassan HA, Mohd S, Hashim R, Mohammad Z, et al. Evaluation of Rapid Colorimetric Lateral Flow Sensor for Hypoxia-Inducible Factor-1 Alpha Detection in High Altitude. Journal of Aerospace Technology and Management. 2026;18. doi:10.1590/jatm.v18.1432

BibTeX
@article{Shaharuddin2026,
  author = {Shaharuddin, Shazreen and Miskan, Maizatullifah and Hassan, Hasliza Abu and Mohd, Shaharuddin and Hashim, Rosnani and Mohammad, Zulkefley and Nordin, Mohd Khairul Nizam and Zainal, Noor Saadiah},
  title = {Evaluation of Rapid Colorimetric Lateral Flow Sensor for Hypoxia-Inducible Factor-1 Alpha Detection in High Altitude},
  journal = {Journal of Aerospace Technology and Management},
  year = {2026},
  volume = {18},
  doi = {10.1590/jatm.v18.1432}
}
Kostenlos starten →