Biomechanical evaluation of prophylactic reinforcement of the linea alba with a novel method of positioning and fixation of polypropylene mesh, in an animal model

Thiago de Almeida Furtado, Álvaro Cota Carvalho, Marcelo Lopes Furtado, Luiz Ronaldo Alberti, Diego Paim de Carvalho Garcia

Acta Cirúrgica Brasileira · 2025

DOI: 10.1590/acb405325 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Acta Cirúrgica Brasileira, 2025. Verfasst von Thiago de Almeida Furtado und 4 weiteren Autor:innen. Beteiligte Einrichtung: Hospital Felício Rocho - Departamento de Ciências Médicas - Belo Horizonte (MG) - Brazil. Hauptthemen laut MEDLINE: Surgical Mesh, Polypropylenes, Abdominal Wall, Cicatrix. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To evaluate the effectiveness of a new format of prophylactic mesh, with a new method of placement.

Methods

Rabbits were randomly distributed into four groups: control rabbits without laparotomy group; sutured rabbits (SR); light-weight mesh rabbits (LWMR); and heavy-weight mesh rabbits (HWMR). The meshes were cut to a size of 10 cm in length by 1 cm in width. A longitudinal, median abdominal incision, 11 cm in length, was performed, followed by an incision over the linea alba, encompassing the entire thickness of the abdominal wall. On the 91st postoperative day, the animals were killed for linea alba scar evaluation.

Results

There was a significant difference among the evaluated groups concerning elongation, maximum load, and elasticity modulus. HWMR and LWMR were statistically different from controls regarding elongation. As for the elasticity modulus, SR presented a higher mean when compared to the others. Microscopic visual analysis showed greater fibrotic scarring with a larger amount of implanted material in HWMR.

Conclusion

The reinforcement of scars with polypropylene mesh does not increase tensile strength when compared to the use of sutures. Mesh implantation results in scar remodeling with greater fibrosis, leading to increased elongation. However, midline reinforcement using only sutures has greater elasticity than the groups reinforced with mesh.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Surgical MeshPolypropylenesAbdominal WallCicatrixHernia, VentralAnimalsRabbitsBiomechanical PhenomenaTensile StrengthRandom AllocationDisease Models, AnimalModels, AnimalSuture TechniquesMaterials TestingMaleReproducibility of Results

Substanzen

Polypropylenes

Autor:innen und Institutionen

  • Hospital Felício Rocho - Departamento de Ciências Médicas - Belo Horizonte (MG) - Brazil.
  • Universidade Estadual Paulista - General Surgery Department - Faculdade de Botucatu (SP) - Brazil.
  • Universidade Federal de Minas Gerais - Santa Casa BH - Belo Horizonte (MG) - Brazil.

Zitieren

APA

Furtado, T. A., Carvalho, Á. C., Furtado, M. L., Alberti, L. R., & Garcia, D. P. C. (2025). Biomechanical evaluation of prophylactic reinforcement of the linea alba with a novel method of positioning and fixation of polypropylene mesh, in an animal model. Acta Cirúrgica Brasileira. https://doi.org/10.1590/acb405325

Vancouver

Furtado TA, Carvalho ÁC, Furtado ML, Alberti LR, Garcia DPC. Biomechanical evaluation of prophylactic reinforcement of the linea alba with a novel method of positioning and fixation of polypropylene mesh, in an animal model. Acta Cirúrgica Brasileira. 2025. doi:10.1590/acb405325

BibTeX
@article{Furtado2025,
  author = {Furtado, Thiago de Almeida and Carvalho, Álvaro Cota and Furtado, Marcelo Lopes and Alberti, Luiz Ronaldo and Garcia, Diego Paim de Carvalho},
  title = {Biomechanical evaluation of prophylactic reinforcement of the linea alba with a novel method of positioning and fixation of polypropylene mesh, in an animal model},
  journal = {Acta Cirúrgica Brasileira},
  year = {2025},
  doi = {10.1590/acb405325}
}
Kostenlos starten →