EUVIMEDEUVIMED entdecken
Crossref

Study of muscle fatigue in isokinetic exercise with estimated conduction velocity and traditional electromyographic indicators

Fabiano Peruzzo Schwartz, Martim Bottaro, Rodrigo Souza Celes, Maria Claudia Pereira, Valdinar de Araújo Rocha Júnior, Francisco Assis de Oliveira Nascimento

Revista Brasileira de Engenharia Biomédica · 2014

DOI: 10.1590/1517-3151.0528 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Revista Brasileira de Engenharia Biomédica, 2014. Verfasst von Fabiano Peruzzo Schwartz und 5 weiteren Autor:innen. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 44 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: In the study of human biomechanics, it is often desirable to evaluate fatigue in the muscles that are involved in performing a particular task. Identifying the phenomena responsible for this condition is a problem that in most cases is complex and requires appropriate research mechanisms. Isokinetic dynamometry (ID) and surface electromyography (SEMG) are two techniques widely used in studies on strength and muscle fatigue. Their effectiveness is conditioned upon a good understanding of their limitations and the adoption of procedures to fully exploit the potential of each one. The main goal of the present study is to verify whether the electromyographic parameters, especially the conduction velocity (CV), are sensitive to the fatigue instauration process within sets of maximal isokinetic contractions. CV is a basic physiological parameter directly related to muscle activity and still little explored in experiments combining ID and SEMG. METHODS: Instrumentation architecture that combines ID and SEMG was used to estimate electromyographic and biomechanical parameters in protocols of maximum intensity isokinetic knee extension exercises. This architecture allows for limiting the parameter estimates to a specific region of isokinetic exercise, called the isokinetic load range (ILR), where one can consider that the angular velocity is constant and the SEMG signals are cyclo-stationary. Electromyographic signals were acquired using an array of electrodes. CONCLUSION: The results suggest that CV and the other SEMG parameters, including amplitude and frequency descriptors, are sensitive to detect a fatigue process only in protocols that restrict the analysis to ILR and that also bring the subject to a state of fatigue quickly.

Zitieren

APA

Schwartz, F. P., Bottaro, M., Celes, R. S., Pereira, M. C., Júnior, V. D. A. R., & Nascimento, F. A. D. O. (2014). Study of muscle fatigue in isokinetic exercise with estimated conduction velocity and traditional electromyographic indicators. Revista Brasileira de Engenharia Biomédica. https://doi.org/10.1590/1517-3151.0528

Vancouver

Schwartz FP, Bottaro M, Celes RS, Pereira MC, Júnior VDAR, Nascimento FADO. Study of muscle fatigue in isokinetic exercise with estimated conduction velocity and traditional electromyographic indicators. Revista Brasileira de Engenharia Biomédica. 2014. doi:10.1590/1517-3151.0528

BibTeX
@article{Schwartz2014,
  author = {Schwartz, Fabiano Peruzzo and Bottaro, Martim and Celes, Rodrigo Souza and Pereira, Maria Claudia and Júnior, Valdinar de Araújo Rocha and Nascimento, Francisco Assis de Oliveira},
  title = {Study of muscle fatigue in isokinetic exercise with estimated conduction velocity and traditional electromyographic indicators},
  journal = {Revista Brasileira de Engenharia Biomédica},
  year = {2014},
  doi = {10.1590/1517-3151.0528}
}
Kostenlos starten →