IgY antibodies/Cysteamine: simple and effective methodology for electrochemical detection of SARS-CoV-2 S-protein
Memórias do Instituto Oswaldo Cruz · 2025
DOI: 10.1590/0074-02760250074 ↗Kurz gefasst
Fachartikel in der Zeitschrift Memórias do Instituto Oswaldo Cruz, 2025. Verfasst von Ariamna Gandarilla und 8 weiteren Autor:innen. Beteiligte Einrichtung: Universidade Federal do Amazonas, Central Analítica Multidisciplinar, Laboratório de Bioeletrônica e Eletroanalítica, Manaus, AM, Brasil. Hauptthemen laut MEDLINE: Spike Glycoprotein, Coronavirus, SARS-CoV-2, COVID-19, Electrochemical Techniques. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
BACKGROUND The outbreak of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infections was a serious disease that spread rapidly around the world and led to a state of global health emergency. During the pandemic, millions of deaths were notified as result of the progression of the disease to a serious condition. Research into the development of diagnostic tests was very important for the identification and control of new cases. OBJECTIVES In this work a label-free electrochemical platform was developed for sensing of SARS-CoV-2 S-protein. METHODS The S- antibodies (IgY type) from egg yolk were immobilised though stable bonding onto screen-printed gold electrodes surface, which was previously modified with self-assembled monolayers of cysteamine (Cys). The analytical performance of the devices was followed by differential pulse voltammetry after incubation in various concentrations of S-protein. FINDINGS The electrical response exhibited a linear behaviour from 10 to 1000 ng mL-1 [with limit of detection (LOD) of 6.2 ng mL-1]. Also, we confirmed that our method is more sensitive than an enzyme-linked immuno-sorbent assay (ELISA), which was conducted with the same molecules (antibody and antigen) (500-4000 ng mL-1, with LOD = 235 ng mL-1). The immunosensor was selective for S-protein detection, and no significative changes were registered by differential pulse voltammetry in presence of SARS-CoV-2 N-protein. Tests on saliva samples recorded similar results to S protein standards. MAIN CONCLUSIONS The developed immunosensor showed good performance and selectivity, therefore, it can be an alternative method for coronavirus disease 2019 (Covid-19) detecting in saliva samples.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Universidade Federal do Amazonas, Central Analítica Multidisciplinar, Laboratório de Bioeletrônica e Eletroanalítica, Manaus, AM, Brasil.
- Fundação Oswaldo Cruz-Fiocruz, Instituto Leônidas e Maria Deane, Manaus, AM, Brasil.
Zitieren
APA
Gandarilla, A., Romaguera-Barcelay, Y., Glória, J. C., Freire, L., Farias, T., Feitosa, J., Anzola, C., Mariuba, L. A. M., & Brito, W. R. (2025). IgY antibodies/Cysteamine: simple and effective methodology for electrochemical detection of SARS-CoV-2 S-protein. Memórias do Instituto Oswaldo Cruz. https://doi.org/10.1590/0074-02760250074
Vancouver
Gandarilla A, Romaguera-Barcelay Y, Glória JC, Freire L, Farias T, Feitosa J, et al. IgY antibodies/Cysteamine: simple and effective methodology for electrochemical detection of SARS-CoV-2 S-protein. Memórias do Instituto Oswaldo Cruz. 2025. doi:10.1590/0074-02760250074
BibTeX
@article{Gandarilla2025,
author = {Gandarilla, Ariamna and Romaguera-Barcelay, Yonny and Glória, Juliane Corrêa and Freire, Luciana and Farias, Taisa and Feitosa, Jessica and Anzola, Carlos and Mariuba, Luís André Morais and Brito, Walter Ricardo},
title = {IgY antibodies/Cysteamine: simple and effective methodology for electrochemical detection of SARS-CoV-2 S-protein},
journal = {Memórias do Instituto Oswaldo Cruz},
year = {2025},
doi = {10.1590/0074-02760250074}
}