EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Comparison of Trendelenburg Tilt Angles 0°, 10°, and 25° on The Diameter of The Internal Jugular Vein And Optical Nerve Sheath

Rahman Rais, Doddy Tavianto, Ricky Aditya, Harry Galuh

Jurnal Anestesi Perioperatif · 23.04.2026 · 14 (1) · 44-51

DOI: 10.15851/jap.v14n1.4243 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Jurnal Anestesi Perioperatif, online erschienen am 23.04.2026. Verfasst von Rahman Rais und 3 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The trendelenburg position is widely utilized to facilitate central venous cannulation. However, the optimal angle to balance efficacy and safety remains debated.

Methods

This experimental study aimed to compare the impact of 0°, 10°, and 25° trendelenburg tilt angles on internal jugular vein (IJV) and optic nerve sheath (ONS) diameters in 28 healthy adults. Measurements of maximal diameters were performed using ultrasound at each specified angle from May to June 2024.

Results

Results demonstrated that while both 10° and 25° positions significantly increased IJV and ONS diameters compared to 0° (P4.5 mm) in five subjects. In contrast, the 10° position achieved a significant increase in IJV diameter while successfully maintaining ONS measurements within safe limits.

Discussion

The findings suggest that although greater trendelenburg angles enhance IJV dilation, they may also increase ONS diameter beyond safe thresholds, raising the risk of elevated intracranial pressure. Therefore, balancing vascular access benefits with neurological safety is essential when determining the appropriate tilt angle.

Conclusion

A 10° trendelenburg tilt is recommended as the optimal angle to increase IJV diameter without elevating ONS diameter in healthy populations.

Zitieren

APA

Rais, R., Tavianto, D., Aditya, R., & Galuh, H. (2026). Comparison of Trendelenburg Tilt Angles 0°, 10°, and 25° on The Diameter of The Internal Jugular Vein And Optical Nerve Sheath. Jurnal Anestesi Perioperatif, 14(1), 44-51. https://doi.org/10.15851/jap.v14n1.4243

Vancouver

Rais R, Tavianto D, Aditya R, Galuh H. Comparison of Trendelenburg Tilt Angles 0°, 10°, and 25° on The Diameter of The Internal Jugular Vein And Optical Nerve Sheath. Jurnal Anestesi Perioperatif. 2026;14(1):44-51. doi:10.15851/jap.v14n1.4243

BibTeX
@article{Rais2026,
  author = {Rais, Rahman and Tavianto, Doddy and Aditya, Ricky and Galuh, Harry},
  title = {Comparison of Trendelenburg Tilt Angles 0°, 10°, and 25° on The Diameter of The Internal Jugular Vein And Optical Nerve Sheath},
  journal = {Jurnal Anestesi Perioperatif},
  year = {2026},
  volume = {14},
  number = {1},
  pages = {44--51},
  doi = {10.15851/jap.v14n1.4243}
}
Kostenlos starten →