Additional value of microvascular flow imaging in the assessment of cystic and solid renal lesions
Physiology International · 2023
DOI: 10.1556/2060.2022.00133 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physiology International, 2023. Verfasst von Ákos Járay und 4 weiteren Autor:innen. Beteiligte Einrichtung: 1Department of Medical Imaging, Medical School, University of Pécs, Pécs, Hungary. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Kidney Neoplasms. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Contrast enhanced ultrasound (CEUS) is increasingly used in the evaluation of renal lesions, however, its availability remains limited. Thus, sensitive noncontrast ultrasound evaluation of renal lesion vascularity is an unmet need.
Methods
In this single-center, retrospective study we assessed microvascular flow imaging (MV-flow) compared to CEUS in the evaluation of complex renal cysts and solid lesions. Out of 92 patients 28 were evaluated with both CEUS and MV-flow. Color Doppler, CEUS, and MV-flow was performed in 13 cases, whilst MV-flow, CEUS, and contrast-enhanced MV-flow (CE-MV-flow) was done in 16 cases. The CEUS diagnosis was considered gold standard.
Results
MV-flow showed a substantial agreement with the CEUS diagnosis (weighted Kappa = 0.806), excluding equivocal lesions (Bosniak 2F). MV-flow substantially outperformed color Doppler (weighted Kappa = 0.77 vs. 0.133). The agreement of CE-MV-flow and MV-flow was comparable (weighted Kappa = 0.79 vs. 0.69).
Conclusion
MV-flow significantly improves evaluation of renal lesion vascularity compared to conventional techniques. However, the sensitivity is limited for equivocal lesions (e.g. Bosniak 2F cysts). Thus, MV-flow should be used as an ancillary technique, not as a substitute to CEUS. Current MV-flow presets are ill-suited for postcontrast imaging, therefore specific presets optimized for this purpose are needed to establish its potential.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- 1Department of Medical Imaging, Medical School, University of Pécs, Pécs, Hungary.
- 2Department of Pathology, Medical School, University of Pécs, Pécs, Hungary.
- 3Molecular Pharmacology Research Team and Centre for Neuroscience, János Szentágothai Research Centre, University of Pécs, Hungary.
ORCID-Profile: Bálint Botz
Zitieren
APA
Járay, Á., Farkas, P. I., Semjén, D., Battyáni, I., & Botz, B. (2023). Additional value of microvascular flow imaging in the assessment of cystic and solid renal lesions. Physiology International. https://doi.org/10.1556/2060.2022.00133
Vancouver
Járay Á, Farkas PI, Semjén D, Battyáni I, Botz B. Additional value of microvascular flow imaging in the assessment of cystic and solid renal lesions. Physiology International. 2023. doi:10.1556/2060.2022.00133
BibTeX
@article{Jray2023,
author = {Járay, Ákos and Farkas, Péter István and Semjén, Dávid and Battyáni, István and Botz, Bálint},
title = {Additional value of microvascular flow imaging in the assessment of cystic and solid renal lesions},
journal = {Physiology International},
year = {2023},
doi = {10.1556/2060.2022.00133}
}
EUVIMED