EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Additional value of microvascular flow imaging in the assessment of cystic and solid renal lesions

Ákos Járay, Péter István Farkas, Dávid Semjén, István Battyáni, Bálint Botz iD

Physiology International · 2023

DOI: 10.1556/2060.2022.00133 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physiology International, 2023. Verfasst von Ákos Járay und 4 weiteren Autor:innen. Beteiligte Einrichtung: 1Department of Medical Imaging, Medical School, University of Pécs, Pécs, Hungary. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Kidney Neoplasms. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Contrast enhanced ultrasound (CEUS) is increasingly used in the evaluation of renal lesions, however, its availability remains limited. Thus, sensitive noncontrast ultrasound evaluation of renal lesion vascularity is an unmet need.

Methods

In this single-center, retrospective study we assessed microvascular flow imaging (MV-flow) compared to CEUS in the evaluation of complex renal cysts and solid lesions. Out of 92 patients 28 were evaluated with both CEUS and MV-flow. Color Doppler, CEUS, and MV-flow was performed in 13 cases, whilst MV-flow, CEUS, and contrast-enhanced MV-flow (CE-MV-flow) was done in 16 cases. The CEUS diagnosis was considered gold standard.

Results

MV-flow showed a substantial agreement with the CEUS diagnosis (weighted Kappa = 0.806), excluding equivocal lesions (Bosniak 2F). MV-flow substantially outperformed color Doppler (weighted Kappa = 0.77 vs. 0.133). The agreement of CE-MV-flow and MV-flow was comparable (weighted Kappa = 0.79 vs. 0.69).

Conclusion

MV-flow significantly improves evaluation of renal lesion vascularity compared to conventional techniques. However, the sensitivity is limited for equivocal lesions (e.g. Bosniak 2F cysts). Thus, MV-flow should be used as an ancillary technique, not as a substitute to CEUS. Current MV-flow presets are ill-suited for postcontrast imaging, therefore specific presets optimized for this purpose are needed to establish its potential.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, X-Ray ComputedKidney NeoplasmsHumansRetrospective StudiesContrast MediaKidneyUltrasonography

Stichwörter der Autor:innen

Bosniak classificationCEUSMV-flowcontrast-enhanced ultrasoundmicrovascular flow imagingrenal complex cystic masses

Substanzen

Contrast Media

Autor:innen und Institutionen

  • 1Department of Medical Imaging, Medical School, University of Pécs, Pécs, Hungary.
  • 2Department of Pathology, Medical School, University of Pécs, Pécs, Hungary.
  • 3Molecular Pharmacology Research Team and Centre for Neuroscience, János Szentágothai Research Centre, University of Pécs, Hungary.

ORCID-Profile: Bálint Botz

Zitieren

APA

Járay, Á., Farkas, P. I., Semjén, D., Battyáni, I., & Botz, B. (2023). Additional value of microvascular flow imaging in the assessment of cystic and solid renal lesions. Physiology International. https://doi.org/10.1556/2060.2022.00133

Vancouver

Járay Á, Farkas PI, Semjén D, Battyáni I, Botz B. Additional value of microvascular flow imaging in the assessment of cystic and solid renal lesions. Physiology International. 2023. doi:10.1556/2060.2022.00133

BibTeX
@article{Jray2023,
  author = {Járay, Ákos and Farkas, Péter István and Semjén, Dávid and Battyáni, István and Botz, Bálint},
  title = {Additional value of microvascular flow imaging in the assessment of cystic and solid renal lesions},
  journal = {Physiology International},
  year = {2023},
  doi = {10.1556/2060.2022.00133}
}
Kostenlos starten →