EUVIMEDEUVIMED entdecken
Crossref

Variations in exercise ventilation in hypoxia will affect oxygen uptake

J A Loeppky, R M Salgado, A C Sheard, D O Kuethe, C M Mermier

Physiology International · 17.10.2020 · 107 (3) · 431-443

DOI: 10.1556/2060.2020.00031 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physiology International, erschienen am 17.10.2020. Verfasst von J A Loeppky und 4 weiteren Autor:innen. Beteiligte Einrichtung: 1Department of Health, Exercise and Sports Sciences, University of New Mexico, Albuquerque, NM 87131, Canada. Hauptthemen laut MEDLINE: Exercise Test, Hypoxia. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 90 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Reports of VO 2 response differences between normoxia and hypoxia during incremental exercise do not agree. In this study VO 2 and V E were obtained from 15-s averages at identical work rates during continuous incremental cycle exercise in 8 subjects under ambient pressure (633 mmHg ≈1,600 m) and during duplicate tests in acute hypobaric hypoxia (455 mmHg ≈4,350 m), ranging from 49 to 100% of VO 2 peak in hypoxia and 42–87% of VO 2 peak in normoxia. The average VO 2 was 96 mL/min (619 mL) lower at 455 mmHg (n.s. P = 0.15) during ramp exercises. Individual response points were better described by polynomial than linear equations (mL/min/W). The V E was greater in hypoxia, with marked individual variation in the differences which correlated significantly and directly with the VO 2 difference between 455 mmHg and 633 mmHg ( P = 0.002), likely related to work of breathing ( W b ). The greater V E at 455 mmHg resulted from a greater breathing frequency. When a subject's hypoxic ventilatory response is high, the extra work of breathing reduces mechanical efficiency ( E ). Mean ∆ E calculated from individual linear slopes was 27.7 and 30.3% at 633 and 455 mmHg, respectively (n.s.). Gross efficiency (GE) calculated from mean VO 2 and work rate and correcting for W b from a V E –VO 2 relationship reported previously, gave corresponding values of 20.6 and 21.8 ( P = 0.05). Individual variation in V E among individuals overshadows average trends, as also apparent from other reports comparing hypoxia and normoxia during progressive exercise and must be considered in such studies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Exercise TestHypoxiaExerciseHumansOxygenOxygen Consumption

Stichwörter der Autor:innen

altitude acclimatizationhypobaric hypoxiaincremental exercisemechanical efficiencynormobaric hypoxiawork of breathing

Substanzen

Oxygen

Autor:innen und Institutionen

  • 1Department of Health, Exercise and Sports Sciences, University of New Mexico, Albuquerque, NM 87131, Canada.
  • 2Research Section, VA Medical Center, Albuquerque, NM 87108, Canada.
  • 3United States Army Research, Institute of Environmental Medicine, Thermal and Mountain Medicine Division, Natick, MA 01760, USA.
  • 4School of Kinesiology and Nutritional Science, California State University, Los Angeles, CA 90032, USA.
  • 5New Mexico Resonance, Albuquerque, NM 87106, Canada.
  • 6Department of Health, Exercise and Sports Sciences, University of New Mexico, Albuquerque, NM 87131, Canada.

Zitieren

APA

Loeppky, J. A., Salgado, R. M., Sheard, A. C., Kuethe, D. O., & Mermier, C. M. (2020). Variations in exercise ventilation in hypoxia will affect oxygen uptake. Physiology International, 107(3), 431-443. https://doi.org/10.1556/2060.2020.00031

Vancouver

Loeppky JA, Salgado RM, Sheard AC, Kuethe DO, Mermier CM. Variations in exercise ventilation in hypoxia will affect oxygen uptake. Physiology International. 2020;107(3):431-443. doi:10.1556/2060.2020.00031

BibTeX
@article{Loeppky2020,
  author = {Loeppky, J A and Salgado, R M and Sheard, A C and Kuethe, D O and Mermier, C M},
  title = {Variations in exercise ventilation in hypoxia will affect oxygen uptake},
  journal = {Physiology International},
  year = {2020},
  volume = {107},
  number = {3},
  pages = {431--443},
  doi = {10.1556/2060.2020.00031}
}
Kostenlos starten →