Optimum angle of using saw teeth roof instead of flat roof and reducing energy
International Review of Applied Sciences and Engineering · 08.07.2026 · 17 (2) · 238-246
DOI: 10.1556/1848.2026.01078 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Review of Applied Sciences and Engineering, erschienen am 08.07.2026. Verfasst von Aveen M. Abdulwahaab und 4 weiteren Autor:innen. Die Arbeit nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Reducing heat gain, and thus cooling load, is a sustainability requirement. It contributes significantly to achieving sustainability by reducing energy consumption, reducing harmful emissions, and improving the environment. This can be achieved through effective thermal insulation, the use of sustainable building materials, and building designs that minimize heat loss. This research investigated the effect of building design through the changing of the roof design by converting a normal horizontal roof into multiple inclined roofs, as well as the effects to cooling loads. This study involved changing the roof slope to a saw tooth shaped wavy shape at various angles ranging from 0 to 60°, and for three different cases of the air gap generated in inclined roofs. The effect of coating the roof surface with ordinary paint and a reflective paint was also compared. The best results were achieved when the saw tooth shaped roof was inclined at an angle of 30° and in case (A), i.e., when the air gap was closed day and night. The annual cooling load value of the test room was 16.1 °C, less than in other cases. The highest value of percentage reduction in the cooling load was 9.1%. The value of annual cooling load at the ordinary surface was 83.4 Kw m −2 , but the value was 58.3 Kw m −2 , with the reflective surface. When exposed to direct sunlight, as is well known, the effect of direct sunlight far outweighs that of indirect sunlight. Consequently, the amount of heat transferred to the building decreases, reducing the operating time of air conditioning units. This, in turn, lowers the building's electricity consumption and results in savings in energy purchase costs. The optimal tilt angle for small roofs has been studied to maximize energy savings.
Zitieren
APA
Abdulwahaab, A. M., Shukri, A. T., Hasan, H. A., Zainal, O. A., & Hasan, A. A. (2026). Optimum angle of using saw teeth roof instead of flat roof and reducing energy. International Review of Applied Sciences and Engineering, 17(2), 238-246. https://doi.org/10.1556/1848.2026.01078
Vancouver
Abdulwahaab AM, Shukri AT, Hasan HA, Zainal OA, Hasan AA. Optimum angle of using saw teeth roof instead of flat roof and reducing energy. International Review of Applied Sciences and Engineering. 2026;17(2):238-246. doi:10.1556/1848.2026.01078
BibTeX
@article{Abdulwahaab2026,
author = {Abdulwahaab, Aveen M. and Shukri, Alaa T. and Hasan, Hadeel A. and Zainal, Omer A. and Hasan, Atif A.},
title = {Optimum angle of using saw teeth roof instead of flat roof and reducing energy},
journal = {International Review of Applied Sciences and Engineering},
year = {2026},
volume = {17},
number = {2},
pages = {238--246},
doi = {10.1556/1848.2026.01078}
}
EUVIMED