Accuracy of dynamic three-dimensional magnetic resonance perfusion imaging for the detection of coronary artery disease in patients with reduced ejection fraction

Sabrina Oebel, Alexander Gotschy, Ingo Paetsch, Cosima Jahnke, Sven Plein, Rolf Gebker, Sandra Hamada, Michael Frick, Jochen von Spiczak, Malgorzata Polacin, Frank Enseleit, Nikolaus Marx und 5 weitere

Imaging · 2021

DOI: 10.1556/1647.2020.00007 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Imaging, 2021. Verfasst von Sabrina Oebel und 16 weiteren Autor:innen. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Swiss National Science Foundation, Bayer Healthcare, Philips Healthcare and the Swiss Heart Foundation.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

To assess the accuracy of 3D cardiovascular magnetic resonance (CMR) perfusion imaging for the detection of coronary artery disease (CAD) against fractional flow reserve (FFR) and quantitative coronary angiography (QCA) in patients with reduced ejection fraction (EF).

Methods

Out of 447 patients who underwent 3D CMR perfusion imaging (at 1.5 and 3.0 T under adenosine stress and at rest) at 5 European centers, 86 cases with an EF ≤50% were identified (mean age 64 ± 11 yrs, 80% male). Significant CAD was defined as a FFR value 50%. 86 individuals matched for age, gender and major cardiovascular risk factors, were chosen as the control group.

Results

The prevalence of CAD defined by FFR (50%), P = 0.4). In relation to FFR, 3D perfusion imaging yielded a sensitivity of 84.5% (95% CI 76.0–90.4) and specificity of 77.3% (95% CI 66.7–85.3). The sensitivity of perfusion imaging was higher in patients with an EF≤50% (90.2 vs. 78.3%, P = 0.1) whereas specificity showed the reverse (62.9 vs. 90.0%, P = 0.005) The diagnostic accuracy was comparable in both subgroups (AUC 79.1 vs. 83.7%, P = 0.25). According to QCA, the prevalence of CAD was 78 vs. 72% ( P = 0.4). Perfusion imaging yielded a sensitivity and specificity of 82.1 vs. 62.9%, P = 0.01 and 79.0 vs. 95.8%, P = 0.09 respectively with a high diagnostic accuracy in both subgroups (AUC 82.0 vs. 80.5%).

Conclusion

3D-CMR perfusion imaging yields a high sensitivity and diagnostic accuracy with regards to the detection of significant CAD irrespective of left ventricular (LV) systolic function.

Förderung

  • Swiss National Science Foundation
  • Bayer Healthcare
  • Philips Healthcare and the Swiss Heart Foundation

Zitieren

APA

Oebel, S., Gotschy, A., Paetsch, I., Jahnke, C., Plein, S., Gebker, R., Hamada, S., Frick, M., Spiczak, J. V., Polacin, M., Enseleit, F., Marx, N., Lüscher, T. F., Ruschitzka, F., Kozerke, S., Alkadhi, H., & Manka, R. (2021). Accuracy of dynamic three-dimensional magnetic resonance perfusion imaging for the detection of coronary artery disease in patients with reduced ejection fraction. Imaging. https://doi.org/10.1556/1647.2020.00007

Vancouver

Oebel S, Gotschy A, Paetsch I, Jahnke C, Plein S, Gebker R, et al. Accuracy of dynamic three-dimensional magnetic resonance perfusion imaging for the detection of coronary artery disease in patients with reduced ejection fraction. Imaging. 2021. doi:10.1556/1647.2020.00007

BibTeX
@article{Oebel2021,
  author = {Oebel, Sabrina and Gotschy, Alexander and Paetsch, Ingo and Jahnke, Cosima and Plein, Sven and Gebker, Rolf and Hamada, Sandra and Frick, Michael and Spiczak, Jochen von and Polacin, Malgorzata and Enseleit, Frank and Marx, Nikolaus and Lüscher, Thomas F. and Ruschitzka, Frank and Kozerke, Sebastian and Alkadhi, Hatem and Manka, Robert},
  title = {Accuracy of dynamic three-dimensional magnetic resonance perfusion imaging for the detection of coronary artery disease in patients with reduced ejection fraction},
  journal = {Imaging},
  year = {2021},
  doi = {10.1556/1647.2020.00007}
}
Kostenlos starten →