EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Development and validation of a size exclusion chromatography method for aggregate analysis in Pramlintide acetate injection using analytical quality by design

Asalla Yakaswamy, Marri Pradeep Kumar

Acta Chromatographica · 20.11.2026

DOI: 10.1556/1326.2026.01517 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Acta Chromatographica, erschienen am 20.11.2026. Verfasst von Asalla Yakaswamy und 1 weiteren Autor:innen. Die Arbeit nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Pramlintide acetate (PA), a synthetic 37-amino acid analogue of human amylin used as an adjunct to mealtime insulin therapy in diabetes mellitus, is susceptible to aggregation under physicochemical stress conditions. Rigorous quantification of aggregates is essential for ensuring patient safety and regulatory compliance. This study describes the development and validation of a size exclusion chromatography with ultraviolet detection (SEC-UV) method for aggregate determination in PA injection, implemented within an Analytical Quality by Design (AQbD) framework. An Ishikawa cause-and-effect diagram and qualitative risk assessment identified mobile phase pH, ionic strength (sodium chloride concentration), and column temperature as critical method parameters (CMPs). A three-factor, three-level Box-Behnken design (BBD) comprising 17 experimental runs was employed to optimise four critical analytical attributes (CAAs): chromatographic resolution, detector sensitivity, peak tailing factor, and theoretical plate count. The optimised method employed a BioSep™ SEC-S2000 column (300 × 7.8 mm; 5 µm; 145 Å) with a mobile phase of 0.1 mM sodium acetate buffer (pH 4.53) supplemented with 89.08 mM sodium chloride, at 0.5 mL min −1 , 50.7 °C column temperature, and UV detection at 214 nm. Validation per ICH Q2 (R1) confirmed specificity, linearity ( r 2 = 0.9972; 0.05%–1.0%), precision (%RSD ≤5%), accuracy (87%–101% recovery), limit of detection (0.05%), and limit of quantification (0.10%). Multi-detector SEC-MALS identified the principal thermally induced aggregate as a pentameric species (∼20 kDa). The validated method provides a regulatory-aligned platform for routine stability monitoring and batch release testing of PA formulations, and a transferable model for SEC aggregate method development where isolated reference standards are unavailable.

Zitieren

APA

Yakaswamy, A., & Kumar, M. P. (2026). Development and validation of a size exclusion chromatography method for aggregate analysis in Pramlintide acetate injection using analytical quality by design. Acta Chromatographica. https://doi.org/10.1556/1326.2026.01517

Vancouver

Yakaswamy A, Kumar MP. Development and validation of a size exclusion chromatography method for aggregate analysis in Pramlintide acetate injection using analytical quality by design. Acta Chromatographica. 2026. doi:10.1556/1326.2026.01517

BibTeX
@article{Yakaswamy2026,
  author = {Yakaswamy, Asalla and Kumar, Marri Pradeep},
  title = {Development and validation of a size exclusion chromatography method for aggregate analysis in Pramlintide acetate injection using analytical quality by design},
  journal = {Acta Chromatographica},
  year = {2026},
  doi = {10.1556/1326.2026.01517}
}
Kostenlos starten →