EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

LC-MS/MS monitoring for explosives residues and OGSR with diverse ionization temperatures in soil & hands: 30 minutes for extraction + elution

Harun Şener, Beril Anilanmert, Murat Emrah Mavis, Gokce Goksu Gursu, Salih Cengiz

Acta Chromatographica · 02.06.2022 · 34 (3) · 304-314

DOI: 10.1556/1326.2021.00930 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Acta Chromatographica, erschienen am 02.06.2022. Verfasst von Harun Şener und 4 weiteren Autor:innen. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Istanbul University Scientific Research Foundation, Ministry of Defence and the Machinery and Chemical Corporation, SEM Group.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A fast LC-APCI-MS/MS screening/confirmation method was developed and validated for trace analyses of 18 analytes which are explosives and organic gun shot residues including the challenging ones with diverse ionization conditions, in soil and on hands. (+) and (−) ionization modes were used after a single-step, low-volume solvent extraction procedure developed using methanol. Tape-lifting, stub, alcohol wipes, cotton bud were compared for collecting the residues from hands of a shooter. Tape-lifting and stub gave the highest recoveries and tape-lifting was chosen. Gradient elution system using ammonium chloride:methanol was developed. Whole procedure lasted approximately 30 min, was validated in both matrices, applied to real samples as post-blast residues, smokeless powder and the hands of a shooter, after shooting. Most of the recoveries were >80% and since all the precisions were

Förderung

  • Istanbul University Scientific Research Foundation
  • Ministry of Defence and the Machinery and Chemical Corporation
  • SEM Group

Zitieren

APA

Şener, H., Anilanmert, B., Mavis, M. E., Gursu, G. G., & Cengiz, S. (2022). LC-MS/MS monitoring for explosives residues and OGSR with diverse ionization temperatures in soil & hands: 30 minutes for extraction + elution. Acta Chromatographica, 34(3), 304-314. https://doi.org/10.1556/1326.2021.00930

Vancouver

Şener H, Anilanmert B, Mavis ME, Gursu GG, Cengiz S. LC-MS/MS monitoring for explosives residues and OGSR with diverse ionization temperatures in soil & hands: 30 minutes for extraction + elution. Acta Chromatographica. 2022;34(3):304-314. doi:10.1556/1326.2021.00930

BibTeX
@article{ener2022,
  author = {Şener, Harun and Anilanmert, Beril and Mavis, Murat Emrah and Gursu, Gokce Goksu and Cengiz, Salih},
  title = {LC-MS/MS monitoring for explosives residues and OGSR with diverse ionization temperatures in soil & hands: 30 minutes for extraction + elution},
  journal = {Acta Chromatographica},
  year = {2022},
  volume = {34},
  number = {3},
  pages = {304--314},
  doi = {10.1556/1326.2021.00930}
}