LC-MS/MS monitoring for explosives residues and OGSR with diverse ionization temperatures in soil & hands: 30 minutes for extraction + elution
Acta Chromatographica · 02.06.2022 · 34 (3) · 304-314
DOI: 10.1556/1326.2021.00930 ↗Kurz gefasst
Fachartikel in der Zeitschrift Acta Chromatographica, erschienen am 02.06.2022. Verfasst von Harun Şener und 4 weiteren Autor:innen. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Istanbul University Scientific Research Foundation, Ministry of Defence and the Machinery and Chemical Corporation, SEM Group.
Abstract (Originalsprache)
A fast LC-APCI-MS/MS screening/confirmation method was developed and validated for trace analyses of 18 analytes which are explosives and organic gun shot residues including the challenging ones with diverse ionization conditions, in soil and on hands. (+) and (−) ionization modes were used after a single-step, low-volume solvent extraction procedure developed using methanol. Tape-lifting, stub, alcohol wipes, cotton bud were compared for collecting the residues from hands of a shooter. Tape-lifting and stub gave the highest recoveries and tape-lifting was chosen. Gradient elution system using ammonium chloride:methanol was developed. Whole procedure lasted approximately 30 min, was validated in both matrices, applied to real samples as post-blast residues, smokeless powder and the hands of a shooter, after shooting. Most of the recoveries were >80% and since all the precisions were
Förderung
- Istanbul University Scientific Research Foundation
- Ministry of Defence and the Machinery and Chemical Corporation
- SEM Group
Zitieren
APA
Şener, H., Anilanmert, B., Mavis, M. E., Gursu, G. G., & Cengiz, S. (2022). LC-MS/MS monitoring for explosives residues and OGSR with diverse ionization temperatures in soil & hands: 30 minutes for extraction + elution. Acta Chromatographica, 34(3), 304-314. https://doi.org/10.1556/1326.2021.00930
Vancouver
Şener H, Anilanmert B, Mavis ME, Gursu GG, Cengiz S. LC-MS/MS monitoring for explosives residues and OGSR with diverse ionization temperatures in soil & hands: 30 minutes for extraction + elution. Acta Chromatographica. 2022;34(3):304-314. doi:10.1556/1326.2021.00930
BibTeX
@article{ener2022,
author = {Şener, Harun and Anilanmert, Beril and Mavis, Murat Emrah and Gursu, Gokce Goksu and Cengiz, Salih},
title = {LC-MS/MS monitoring for explosives residues and OGSR with diverse ionization temperatures in soil & hands: 30 minutes for extraction + elution},
journal = {Acta Chromatographica},
year = {2022},
volume = {34},
number = {3},
pages = {304--314},
doi = {10.1556/1326.2021.00930}
}
EUVIMED