EUVIMEDEUVIMED entdecken
Kohortenstudie

Diagnostic value of metagenomic next-generation sequencing on bronchoalveolar lavage fluid via radial endobronchial ultrasound for peripheral pulmonary infectious lesions: A retrospective cohort study

Mengge Wen iD, Xiaochun Wang

Acta Microbiologica et Immunologica Hungarica · 29.05.2026 · 73 (2) · 211-222

DOI: 10.1556/030.2026.02865 ↗

Kurz gefasst

Kohortenstudie in der Zeitschrift Acta Microbiologica et Immunologica Hungarica, erschienen am 29.05.2026. Verfasst von Mengge Wen und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Respiratory and Critical Care Medicine, Wuyi County First People's Hospital, Wuyi, 321200, China. Hauptthemen laut MEDLINE: Bronchoalveolar Lavage Fluid, High-Throughput Nucleotide Sequencing, Endosonography, Metagenomics. Die Arbeit nennt 56 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The etiological diagnosis of peripheral pulmonary infectious lesions (PPILs) is challenging due to the limitations of conventional microbiological methods (CMMs). This study aimed to evaluate the diagnostic value of metagenomic next-generation sequencing (mNGS) performed on bronchoalveolar lavage fluid (BALF) obtained via radial endobronchial ultrasound (r-EBUS) for PPILs. This single-center, retrospective diagnostic accuracy study enrolled 110 patients with PPILs who underwent r-EBUS-guided BALF between January 2023 and December 2024. BALF samples were subjected to both mNGS and CMMs. The final diagnosis was established by two senior pulmonologists based on a comprehensive review of all clinical data. The diagnostic performance of mNGS and CMMs was compared against this final diagnosis. A definitive diagnosis was established in all 110 patients, with 68 cases identified as infectious lesions and 42 as non-infectious. The sensitivity of mNGS for detecting pathogens in infectious lesions was significantly higher than that of CMMs (89.7% vs. 47.1%, P < 0.001). The overall diagnostic accuracy of mNGS was also superior to CMMs (90.9% vs. 66.4%, P < 0.001). Among patients with positive mNGS results, clinical management was altered in 73.8% of cases based on the findings. mNGS uniquely identified pathogens in 31 cases that were missed by CMMs. For patients with PPILs, mNGS analysis of BALF samples obtained via r-EBUS demonstrates significantly greater diagnostic sensitivity and accuracy than conventional methods. This approach has a substantial impact on clinical decision-making, facilitating targeted antimicrobial therapy and representing a powerful tool in the diagnostic workflow for peripheral pulmonary infections.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Bronchoalveolar Lavage FluidHigh-Throughput Nucleotide SequencingEndosonographyMetagenomicsRespiratory Tract InfectionsHumansRetrospective StudiesFemaleMaleMiddle AgedAgedSensitivity and SpecificityBronchoscopyAdult

Stichwörter der Autor:innen

bronchoalveolar lavage fluidetiological diagnosismetagenomic next-generation sequencingperipheral pulmonary infectious lesionsradial endobronchial ultrasound

Autor:innen und Institutionen

  • Department of Respiratory and Critical Care Medicine, Wuyi County First People's Hospital, Wuyi, 321200, China.

ORCID-Profile: Mengge Wen

Zitieren

APA

Wen, M., & Wang, X. (2026). Diagnostic value of metagenomic next-generation sequencing on bronchoalveolar lavage fluid via radial endobronchial ultrasound for peripheral pulmonary infectious lesions: A retrospective cohort study. Acta Microbiologica et Immunologica Hungarica, 73(2), 211-222. https://doi.org/10.1556/030.2026.02865

Vancouver

Wen M, Wang X. Diagnostic value of metagenomic next-generation sequencing on bronchoalveolar lavage fluid via radial endobronchial ultrasound for peripheral pulmonary infectious lesions: A retrospective cohort study. Acta Microbiologica et Immunologica Hungarica. 2026;73(2):211-222. doi:10.1556/030.2026.02865

BibTeX
@article{Wen2026,
  author = {Wen, Mengge and Wang, Xiaochun},
  title = {Diagnostic value of metagenomic next-generation sequencing on bronchoalveolar lavage fluid via radial endobronchial ultrasound for peripheral pulmonary infectious lesions: A retrospective cohort study},
  journal = {Acta Microbiologica et Immunologica Hungarica},
  year = {2026},
  volume = {73},
  number = {2},
  pages = {211--222},
  doi = {10.1556/030.2026.02865}
}