Factors influencing renal shear wave elastography: effects of probe orientation, respiration, corticomedullary differentiation, and hydration
Journal of Ultrasonography · 30.06.2026 · 26 (105)
DOI: 10.15557/jou.2026.0015 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Ultrasonography, online erschienen am 30.06.2026. Verfasst von Andrzej Materniak und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatric Radiology, Medical University of Lublin,Poland. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Aim
To assess how probe orientation, respiratory phase, hydration, and corticomedullary differentiation affect renal two-dimensional shear wave elastography. Material and methods: Prospective single-center study with four independent sub-studies: (1) probe orientation (long vs. short axis; children, n = 35), (2) respiration (quiet breathing vs. brief mid-expiratory breath-hold; children, n = 20), (3) hydration (adults, n = 12; 700 mL water intake; stiffness at baseline, +20, +40 min), and (4) corticomedullary differentiation with depth assessment (children, n = 29). Shear wave elastography was acquired as five- frame series using 5-mm regions of interest. Sub-studies 1–3 sampled the cortex, whereas sub-study 4 sampled the cortex and renal pyramids at matched depths. Outcomes included per-subject median stiffness (kPa) and interquartile-range-to-median ratio (IQR/M). A quality filter (IQR/M ≤0.30) was applied to all sub-studies except the orientation sub-study. Statistical analysis included the Wilcoxon signed-rank test, Friedman test (hydration), and Spearman’s ρ (depth).
Results
Long-axis orientation reduced variability within measurement series (lower IQR/M) compared with short-axis orientation (p
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Pediatric Radiology, Medical University of Lublin,Poland.
ORCID-Profile: Andrzej Materniak, Grzegorz Jędrzejewski, Andrzej Paweł Wieczorek, Magdalena Woźniak
Zitieren
APA
Materniak, A., Jędrzejewski, G., Wieczorek, A. P., & Woźniak, M. (2026). Factors influencing renal shear wave elastography: effects of probe orientation, respiration, corticomedullary differentiation, and hydration. Journal of Ultrasonography, 26(105). https://doi.org/10.15557/jou.2026.0015
Vancouver
Materniak A, Jędrzejewski G, Wieczorek AP, Woźniak M. Factors influencing renal shear wave elastography: effects of probe orientation, respiration, corticomedullary differentiation, and hydration. Journal of Ultrasonography. 2026;26(105). doi:10.15557/jou.2026.0015
BibTeX
@article{Materniak2026,
author = {Materniak, Andrzej and Jędrzejewski, Grzegorz and Wieczorek, Andrzej Paweł and Woźniak, Magdalena},
title = {Factors influencing renal shear wave elastography: effects of probe orientation, respiration, corticomedullary differentiation, and hydration},
journal = {Journal of Ultrasonography},
year = {2026},
volume = {26},
number = {105},
doi = {10.15557/jou.2026.0015}
}
EUVIMED