EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 3.0

Comparison of manual palpation, 2D carotid ultrasound, and end-tidal carbon dioxide for detecting return of spontaneous circulation

Akin Gullu, Sukru Kockan, Emre Sanci, Erdem Aydin, Ahmet Emir Sari, Asim Enes Ozbek, Huseyin Cahit Halhalli

Clinical and Experimental Emergency Medicine · 2026

DOI: 10.15441/ceem.25.113 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical and Experimental Emergency Medicine, 2026. Verfasst von Akin Gullu und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Emergency Medicine, Sakarya Education and Research Hospital, University of Sakarya, Sakarya, Turkiye. Die Arbeit nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 3.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Healthcare providers frequently spend excessive time attempting to identify a pulse and may have difficulty accurately confirming its presence. Point-of-care carotid artery ultrasonography has been suggested as a potential alternative to manual palpation. This study aimed to evaluate the effectiveness of manual palpation, 2D carotid ultrasonography, and rapid increases in end-tidal carbon dioxide (EtCO2) levels for determining the return of spontaneous circulation (ROSC) in patients with cardiac arrest presenting to an emergency department.

Methods

This was a single-center, prospective, observational study. Nontraumatic adult patients in cardiopulmonary arrest who were brought to the emergency department were included. After cardiac arrest was identified, the following data were recorded: initial arrest rhythm, ultrasonographic and manual pulse assessments, EtCO2 levels, resuscitation duration, and post-ROSC vital signs. The team leader’s judgment was used for ROSC adjudication and served as the reference standard.

Results

The investigation included 88 patients who underwent a total of 642 cycles of cardiopulmonary resuscitation. The area under the curve (AUC) values for 2D carotid ultrasonography, EtCO2, and manual palpation were 0.974, 0.802, and 0.862, respectively (all P

Schlagwörter

Stichwörter der Autor:innen

CapnographyCardiopulmonary arrestCardiopulmonary resuscitationReturn of spontaneous circulationUltrasonography

Autor:innen und Institutionen

  • Department of Emergency Medicine, Sakarya Education and Research Hospital, University of Sakarya, Sakarya, Turkiye.
  • Department of Emergency Medicine, Kocaeli City Hospital, Kocaeli, Turkiye.
  • Department of Emergency Medicine, Izmir Bakircay University, Cigli Training and Research Hospital, Izmir, Turkiye.
  • Department of Emergency Medicine, İstanbul Kanuni Sultan Suleyman Training and Research Hospital, Istanbul, Turkiye.

Zitieren

APA

Gullu, A., Kockan, S., Sanci, E., Aydin, E., Sari, A. E., Ozbek, A. E., & Halhalli, H. C. (2026). Comparison of manual palpation, 2D carotid ultrasound, and end-tidal carbon dioxide for detecting return of spontaneous circulation. Clinical and Experimental Emergency Medicine. https://doi.org/10.15441/ceem.25.113

Vancouver

Gullu A, Kockan S, Sanci E, Aydin E, Sari AE, Ozbek AE, et al. Comparison of manual palpation, 2D carotid ultrasound, and end-tidal carbon dioxide for detecting return of spontaneous circulation. Clinical and Experimental Emergency Medicine. 2026. doi:10.15441/ceem.25.113

BibTeX
@article{Gullu2026,
  author = {Gullu, Akin and Kockan, Sukru and Sanci, Emre and Aydin, Erdem and Sari, Ahmet Emir and Ozbek, Asim Enes and Halhalli, Huseyin Cahit},
  title = {Comparison of manual palpation, 2D carotid ultrasound, and end-tidal carbon dioxide for detecting return of spontaneous circulation},
  journal = {Clinical and Experimental Emergency Medicine},
  year = {2026},
  doi = {10.15441/ceem.25.113}
}
Kostenlos starten →