Endovascular Rescue of Simultaneous Renal Stent Thrombosis: Case Report
Vascular and Endovascular Review · 2018
DOI: 10.15420/ver.2018.1.2 ↗Kurz gefasst
Fallbericht in der Zeitschrift Vascular and Endovascular Review, 2018. Verfasst von Fernando Gallardo Pedrajas und 5 weiteren Autor:innen. Die Arbeit nennt 17 Literaturangaben.
Abstract (Originalsprache)
The chimney/periscope technique has been used to address complex aortic pathologies. This case report aims to report the outcomes of the endovascular management of the acute and simultaneous thrombosis of both renal covered stent grafts after bilateral renal arteries chimney technique for endovascular repair (CH-EVAR) of a juxtarenal abdominal aortic aneurysm. The cause of this early occlusion of stent grafts may be related to how procedures and devices combinations alter the native anatomy. The authors aimed to compare renal artery geometry before and after CH-EVAR to find a possible cause of stent thrombosis.
Zitieren
APA
Pedrajas, F. G., Carvajal, R. R., Martín-Palanca, A., Verdes, R. M., Carbonell, T. H., & Rube, R. L. (2018). Endovascular Rescue of Simultaneous Renal Stent Thrombosis: Case Report. Vascular and Endovascular Review. https://doi.org/10.15420/ver.2018.1.2
Vancouver
Pedrajas FG, Carvajal RR, Martín-Palanca A, Verdes RM, Carbonell TH, Rube RL. Endovascular Rescue of Simultaneous Renal Stent Thrombosis: Case Report. Vascular and Endovascular Review. 2018. doi:10.15420/ver.2018.1.2
BibTeX
@article{Pedrajas2018,
author = {Pedrajas, Fernando Gallardo and Carvajal, Rubén Rodriguez and Martín-Palanca, Alberto and Verdes, Rocio Martin-Palanca and Carbonell, Teresa Hernández and Rube, Rocio Lainez},
title = {Endovascular Rescue of Simultaneous Renal Stent Thrombosis: Case Report},
journal = {Vascular and Endovascular Review},
year = {2018},
doi = {10.15420/ver.2018.1.2}
}
EUVIMED