Effect of Storage to Reusable Equipment Sterility in Neurosurgical Critical Care Unit at a Hospital in Bandung
Indonesian Journal of Clinical Pharmacy · 2014
DOI: 10.15416/ijcp.2014.3.2.61 ↗Kurz gefasst
Fachartikel in der Zeitschrift Indonesian Journal of Clinical Pharmacy, 2014. Verfasst von Arif Budiman und 3 weiteren Autor:innen.
Abstract (Originalsprache)
Neurosurgical Critical Care Unit (NCCU) merupakan ruang perawatan intensif yang memiliki nilai prevalensi Infeksi Rumah Sakit (IRS) yang tinggi sebesar 16,7%. Hal tersebut dikarenakan NCCU digunakan untuk merawat pasien sakit berat dan kritis pascabedah saraf. Tujuan penelitian ini adalah untuk mengetahui sterilitas peralatan pakai ulang pada ruang NCCU dibandingkan dengan ruang penyimpanan Central Sterile Supply Department (CSSD). Pengujian sterilitas meliputi uji sterilitas media, uji fertilitas media serta uji peralatan pakai ulang menggunakan metode transport swab. Pengujian dilakukan selama 28 hari, kemudian diinterpretasikan menggunakan perhitungan odds ratio. Hasil menunjukkan bahwa Ruang NCCU pada hari ke-7 ditemukan peralatan yang terkontaminasi sedangkan pada ruang CSSD baru ditemukan pada hari ke-28. Hal ini menandakan bahwa ruangan CSSD lebih steril dibandingkan ruang penyimpanan NCCU. Walaupun tingkat sterilitas ruang CSSD lebih tinggi dibandingkan dengan ruang NCCU, tidak memberikan pengaruh yang signifikan terhadap sterilitas peralatan pakai ulang. Kata kunci: CSSD, IRS, NCCU, peralatan pakai ulang, sterilitas Effect of Storage to Reusable Equipment Sterility in Neurosurgical Critical Care Unit at a Hospital in Bandung Abstract Neurosurgical Critical Care Unit (NCCU) is an intensive care room which has a high prevalence of Hospital Infection about 16.7%. That is because NCCU is used to treat patient post neurosurgry. This research aims to determine the sterility of reusable equipment from NCCU, compared to Central Sterile Supply Department (CSSD). The sterility test included sterility test of medium, fertility test and trasnport swab method for reuseable equipment test. Tests carried out for 28 days, then interpreted using odds ratio calculation. The result showed that NCCU on day 7 was contaminated, while CSSD was contaminated on day 28. This indicated that CSSD more sterile than NCCU. Although the sterility of CSSD higher than NCCU, did’nt have a significant effect on the sterility of reusable equipment. Key words: CSSD, hospital infection, NCCU, reusable equipment, sterility
Zitieren
APA
Budiman, A., Rindiantika, Y., Kurniawan, I. S., & Hegandari (2014). Effect of Storage to Reusable Equipment Sterility in Neurosurgical Critical Care Unit at a Hospital in Bandung. Indonesian Journal of Clinical Pharmacy. https://doi.org/10.15416/ijcp.2014.3.2.61
Vancouver
Budiman A, Rindiantika Y, Kurniawan IS, Hegandari. Effect of Storage to Reusable Equipment Sterility in Neurosurgical Critical Care Unit at a Hospital in Bandung. Indonesian Journal of Clinical Pharmacy. 2014. doi:10.15416/ijcp.2014.3.2.61
BibTeX
@article{Budiman2014,
author = {Budiman, Arif and Rindiantika, Yokaniza and Kurniawan, Insan S. and Hegandari},
title = {Effect of Storage to Reusable Equipment Sterility in Neurosurgical Critical Care Unit at a Hospital in Bandung},
journal = {Indonesian Journal of Clinical Pharmacy},
year = {2014},
doi = {10.15416/ijcp.2014.3.2.61}
}
EUVIMED