Under the current operating conditions of the Integrated Power System of Ukraine, the reliability and operational safety of thermal power plant equipment are of critical importance. Ensuring long-term operation and evaluating the individual service life of critical turbine components following mechanical damage and repair restorations require a comprehensive investigation of their thermomechanical state. The aim of this study is to perform computational research of the spatial thermal state of the low-pressure rotor of the K-200-130 steam turbine to provide scientific and technical justification for extending its reliable operational life. The research methodology is based on the fundamental principles of transient heat conduction and continuum mechanics, utilizing the finite element method within the SolidWorks environment. A spatial 3D model of the symmetric half of the LPR (approximately 6.2 million elements) was developed with adaptive mesh refinement in stress concentration zones. The model incorporates actual post-repair geometric modifications, specifically a reduction in the shaft journal diameter in the bearing No. 5 area from 435 mm to 420 mm. Second- and third-kind boundary conditions for heat transfer were determined using similarity theory criterion equations, accounting for the thermodynamic and hydrodynamic characteristics of the steam flow in the flow path. Three-dimensional temperature fields of the rotor were obtained for the rated 200 MW load regime and during a transient cold start-up. It was found that under steady-state operation, the metal reaches a thermally stabilized state, with temperatures ranging from 160–170 °C in the steam inlet region to 40–65 °C in the last stages. During cold start-up, significant transience was observed: during rotor rolling and speed acceleration, an extreme radial temperature gradient occurs, with the outer surface heating up to 130–150 °C while inner layers warm up only to 30–40 °C. A notable thermal lag in the warming of the shaft symmetry axis was recorded, resulting from the massive rotor dimensions and the thermophysical properties of 25Cr1Mo1V steel. The resulting temperature fields and gradients provide a foundational basis for subsequent numerical analysis of the rotor’s stress-strain state, evaluation of cumulative low-cycle fatigue damage, and prediction of the power unit's remaining individual service life.

Zitieren

APA

Chernousenko, O. Y., Peshko, V. A., Ryndiuk, D. V., & Bovsunovskyi, A. P. (2026). Modeling the Thermal State of the Low-Pressure Rotor of the K-200-130 Turbine During Start-Up. Journal of Mechanical Engineering, 29(3), 71-79. https://doi.org/10.15407/pmach2026.03.071

Vancouver

Chernousenko OY, Peshko VA, Ryndiuk DV, Bovsunovskyi AP. Modeling the Thermal State of the Low-Pressure Rotor of the K-200-130 Turbine During Start-Up. Journal of Mechanical Engineering. 2026;29(3):71-79. doi:10.15407/pmach2026.03.071

BibTeX
@article{Chernousenko2026,
  author = {Chernousenko, Olha Yu. and Peshko, Vitalii A. and Ryndiuk, Dmytro V. and Bovsunovskyi, Anatolii P.},
  title = {Modeling the Thermal State of the Low-Pressure Rotor of the K-200-130 Turbine During Start-Up},
  journal = {Journal of Mechanical Engineering},
  year = {2026},
  volume = {29},
  number = {3},
  pages = {71--79},
  doi = {10.15407/pmach2026.03.071}
}
Kostenlos starten →