Niveles de referencia de CTDIvol para exploraciones tomogr´aficas de cabeza en pacientes pedi´atricos
Revista de Investigación de Física · 2026
DOI: 10.15381/rif.29i2.24264 ↗Kurz gefasst
Fachartikel in der Zeitschrift Revista de Investigación de Física, 2026. Verfasst von Víctor Infante und 3 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Dose indicators for head computed tomography (CT) studies, such as the volumetric CT Dose Index (CTDIvol) were verified and analyzed for pediatric patients. Simulations of studies using brain exposure techniques were performed on the CT scanner at the National Institute of Child Health (INSN). For this purpose, a PMMA (polymethyl methacrylate) head phantom was used, a material with a density and attenuation capacity similar to that of human tissue. To measure how the radiation dose is distributed at specific points on the phantom, a pencil-type ionization chamber connected to a digital electrometer was used. The electrometer was automatically charged with correction factors to calibrate its external detectors. The average CTDIvol indicator for the age ranges of 0-3 years, 3-5 years, 5-10 years, 10-15 years, and 15-18 years is 26.08 mGy, 26.59 mGy, 34.99 mGy, 35.20 mGy, and 53.40 mGy, respectively. These results are similar to those of studies conducted in North America, Europe, Asia, and Africa. The study identified that the brain dose indicator CTDIvol values for pediatric patients aged 15-18 years are close to those for adult patients. This underscores the need to implement and apply optimized exposure techniques to reduce radiation doses received by pediatric patients.
Zitieren
APA
Infante, V., Figueroa, N., Ballón, J., & Umpire, L. (2026). Niveles de referencia de CTDIvol para exploraciones tomogr´aficas de cabeza en pacientes pedi´atricos. Revista de Investigación de Física. https://doi.org/10.15381/rif.29i2.24264
Vancouver
Infante V, Figueroa N, Ballón J, Umpire L. Niveles de referencia de CTDIvol para exploraciones tomogr´aficas de cabeza en pacientes pedi´atricos. Revista de Investigación de Física. 2026. doi:10.15381/rif.29i2.24264
BibTeX
@article{Infante2026,
author = {Infante, Víctor and Figueroa, Navor and Ballón, Javier and Umpire, Luis},
title = {Niveles de referencia de CTDIvol para exploraciones tomogr´aficas de cabeza en pacientes pedi´atricos},
journal = {Revista de Investigación de Física},
year = {2026},
doi = {10.15381/rif.29i2.24264}
}