Fachartikel in der Zeitschrift European Thyroid Journal, 2024. Verfasst von Karoly Rucz und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Endocrinology, Siofok Hospital, Siofok, Hungary. Hauptthemen laut MEDLINE: Thyroid Nodule, Sensitivity and Specificity, Ultrasonography, Patient Selection. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Objective
The ultrasound evaluation of thyroid nodules (TNs) in patient selection for fine needle aspiration (FNA) requires both uniformly accepted definitions of each nodule characteristic and extensive experience from the examiner. We hypothesized that nodule echogenicity alone may provide comparable performance to more complex approaches in patient selection for FNA. Patients and methods Seven highly experienced investigators from four countries evaluated, online, the ultrasound (US) video recordings of 123 histologically verified TN by answering 17 nodule characteristics-related questions. The diagnostic performances of five TN image reporting and data systems (TIRADS) were compared to making decisions based solely on the echogenicity of the nodule for indicating FNA in 110 nodules ≥10 mm.
Results
In the 10–20 mm size range, the sensitivities and specificities of the five TIRADS systems in identifying malignant nodules were 80.5–91.0% and 31.4–50.9%, respectively. Had FNA been recommended for all hypoechoic nodules, disregarding other US characteristics, comparable sensitivity and specificity (87.5% and 43.4%, respectively) were obtained. Compared to nodules >20 mm, a higher proportion of cancers were hypoechoic in the 10–20 mm size range (87.2% vs 77.8%, P = 0.05). In the 10–20 mm size range, compared to hypoechoic nodules, a significantly lower proportion of isoechoic nodules demonstrated suspicious findings (70.7% vs 30.0%, P < 0.05).
Conclusion
In contrast to >20 mm diameter nodules, the recommendation of FNA may rely on a single US feature, echogenicity, in the 10–20 mm size range. If independently confirmed in larger cohorts, this may simplify nodule evaluation in this size range.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Endocrinology, Siofok Hospital, Siofok, Hungary.
- Department of Endocrinology, Odense University Hospital, Odense, Denmark.
- Endocrinology Unit of Arcispedale S. Maria Nuova, Reggio Emilia, Italy.
- Institute of Medical Imaging, Faculty of Medicine, University of Debrecen, Debrecen, Hungary.
- 1st Department of Medicine, Flohr Ferenc Hospital, Kistarcsa, Hungary.
- Regina Apostolorum Hospital in Albano, Rome, Italy.
ORCID-Profile: Gilles Russ, Endre V Nagy
Zitieren
APA
Rucz, K., Hegedűs, L., Bonnema, S. J., Frasoldati, A., Jambor, L., Kovacs, G. L., Papini, E., Russ, G., Karanyi, Z., Nagy, E. V., & Solymosi, T. (2024). Echogenicity as a standalone nodule characteristic is not inferior to the TIRADS systems in the 10–20 mm nodule diameter range in patient selection for fine needle aspiration: a pilot study. European Thyroid Journal. https://doi.org/10.1530/etj-24-0149
Vancouver
Rucz K, Hegedűs L, Bonnema SJ, Frasoldati A, Jambor L, Kovacs GL, et al. Echogenicity as a standalone nodule characteristic is not inferior to the TIRADS systems in the 10–20 mm nodule diameter range in patient selection for fine needle aspiration: a pilot study. European Thyroid Journal. 2024. doi:10.1530/etj-24-0149
BibTeX
@article{Rucz2024,
author = {Rucz, Karoly and Hegedűs, Laszlo and Bonnema, Steen Joop and Frasoldati, Andrea and Jambor, Laszlo and Kovacs, Gabor Laszlo and Papini, Enrico and Russ, Gilles and Karanyi, Zsolt and Nagy, Endre V and Solymosi, Tamas},
title = {Echogenicity as a standalone nodule characteristic is not inferior to the TIRADS systems in the 10–20 mm nodule diameter range in patient selection for fine needle aspiration: a pilot study},
journal = {European Thyroid Journal},
year = {2024},
doi = {10.1530/etj-24-0149}
}
EUVIMED