EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

A Pilot Project for the Expansion of the External Quality Assessment Program in Transfusion Medicine: Anti-D Titer Test

Yousun Chung, Jin Seok Kim, Hee-Jeong Youk, Sang-Hyun Hwang, Heung-Bum Oh, Hyungsuk Kim, Dae-Hyun Ko

Journal of Laboratory Medicine and Quality Assurance · 2022

DOI: 10.15263/jlmqa.2022.44.2.99 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Laboratory Medicine and Quality Assurance, 2022. Verfasst von Yousun Chung und 6 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Korean Association of External Quality Assessment Service.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Many test items in transfusion medicine that are still not included in the Korean Association of External Quality Assessment Service.We performed a pilot project of anti-D titer test for the expansion of proficiency testing program in transfusion medicine.

Methods

Proficiency testing materials with low (BBS2-21-01) and high (BBS2-21-02) anti-D titer were sent to 53 laboratories that agreed to participate in the pilot project for the 2nd Korean Association of External Quality Assessment Service on Transfusion Medicine in 2021.The results were entered on the website of the Korean Association of External Quality Assessment Service (http://eqas.keqas.org/).

Results

A total of 47 laboratories submitted the results.For BBS2-21-01, the intended response of anti-D titer was 4-16 for tube technique with antihuman globulin (AHG) and 16-64 for column agglutination technique (CAT) with AHG.Meanwhile, for BBS2-21-02, the intended response was 8-32 for tube technique with AHG and 32-128 for CAT with AHG.The proportion of acceptable results was 90.9%-95.5% for tube technique with AHG and 95.8%-100.0%for CAT with AHG.

Conclusions

The pilot project of anti-D titer test was successfully performed.This project will be expanded to a biannual proficiency testing program for anti-D antibody titer in the Korean Association of External Quality Assessment Service starting in 2022.

Förderung

  • Korean Association of External Quality Assessment Service

Zitieren

APA

Chung, Y., Kim, J. S., Youk, H., Hwang, S., Oh, H., Kim, H., & Ko, D. (2022). A Pilot Project for the Expansion of the External Quality Assessment Program in Transfusion Medicine: Anti-D Titer Test. Journal of Laboratory Medicine and Quality Assurance. https://doi.org/10.15263/jlmqa.2022.44.2.99

Vancouver

Chung Y, Kim JS, Youk H, Hwang S, Oh H, Kim H, et al. A Pilot Project for the Expansion of the External Quality Assessment Program in Transfusion Medicine: Anti-D Titer Test. Journal of Laboratory Medicine and Quality Assurance. 2022. doi:10.15263/jlmqa.2022.44.2.99

BibTeX
@article{Chung2022,
  author = {Chung, Yousun and Kim, Jin Seok and Youk, Hee-Jeong and Hwang, Sang-Hyun and Oh, Heung-Bum and Kim, Hyungsuk and Ko, Dae-Hyun},
  title = {A Pilot Project for the Expansion of the External Quality Assessment Program in Transfusion Medicine: Anti-D Titer Test},
  journal = {Journal of Laboratory Medicine and Quality Assurance},
  year = {2022},
  doi = {10.15263/jlmqa.2022.44.2.99}
}
Kostenlos starten →