Experimental Wave-Based Assessment of Liquefaction Resistance for Different Degrees of Saturation

Fausto Molina-Gómez, António Viana da Fonseca, Cristiana Ferreira, Bernardo Caicedo

Geotechnical Testing Journal · 01.11.2023 · 46 (6) · 968-985

DOI: 10.1520/gtj20230299 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Geotechnical Testing Journal, online erschienen am 03.10.2023. Verfasst von Fausto Molina-Gómez und 3 weiteren Autor:innen. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 57 Literaturangaben. Gefördert von: Institute of R&D in Structures and Construction, Fundação para a Ciência e a Tecnologia.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper presents the results of an experimental program carried out in the laboratory aimed at assessing the liquefaction resistance by correlations between longitudinal wave (P-wave) and shear wave (S-wave) velocities (VP and VS) and cyclic stress ratio from triaxial testing (CSRCTx) for different degrees of saturation (Sr). The liquefaction resistance was assessed using a cyclic triaxial apparatus equipped with Hall-effect transducers and bender elements, combining stress-based (large-strain level) and wave-based (small-strain level) approaches. These tests were carried out in soil specimens at relatively high degrees of saturation, which were estimated during testing by VP measurements interpreted using Biot’s theory. The results revealed that, for the same relative density and confinement stress, the S-wave-based approach did not predict the liquefaction resistance well because of the negligible variation in the stress state and soil stiffness for the assessed Sr values, which were above the air-entry value. In turn, the P-wave-based approach effectively predicted the liquefaction resistance increment of the TP-Lisbon sand for different Sr conditions because of the strong dependency of P-wave propagation on the degree of saturation in granular media. This is a consequence of the most relevant factor conditioning the pore pressure buildup in partially saturated sands, e.g., the compressibility of the occluded air bubbles, which can be detected by VP but not by VS.

Förderung

  • Institute of R&D in Structures and Construction
  • Fundação para a Ciência e a Tecnologia

Zitieren

APA

Molina-Gómez, F., Fonseca, A. V. D., Ferreira, C., & Caicedo, B. (2023). Experimental Wave-Based Assessment of Liquefaction Resistance for Different Degrees of Saturation. Geotechnical Testing Journal, 46(6), 968-985. https://doi.org/10.1520/gtj20230299

Vancouver

Molina-Gómez F, Fonseca AVD, Ferreira C, Caicedo B. Experimental Wave-Based Assessment of Liquefaction Resistance for Different Degrees of Saturation. Geotechnical Testing Journal. 2023;46(6):968-985. doi:10.1520/gtj20230299

BibTeX
@article{MolinaGmez2023,
  author = {Molina-Gómez, Fausto and Fonseca, António Viana da and Ferreira, Cristiana and Caicedo, Bernardo},
  title = {Experimental Wave-Based Assessment of Liquefaction Resistance for Different Degrees of Saturation},
  journal = {Geotechnical Testing Journal},
  year = {2023},
  volume = {46},
  number = {6},
  pages = {968--985},
  doi = {10.1520/gtj20230299}
}
Kostenlos starten →