Isoprene, a volatile organic compound in human breath, has emerged as a promising biomarker for non-invasive monitoring of hypoglycemia. However, its low concentration (ppb level) and demands for low energyconsuming constituents pose significant challenges for realtime detection. In this work, we present a room-temperature chemoresistive gas sensor based on a nanocomposite of laserreduced graphene oxide (LrGO) and tin oxide nanoparticles (SnO2 NPs), fabricated via a photolithography-free in-situ laser patterning technique. The LrGO-SnO2 sensing film was optimized through controlled nanomaterial dispersion and in-situ laser reduction, enabling the construction of interdigitated electrode structures directly on flexible Kapton substrates. The sensor exhibits a wide detection range (0.5-100 ppm), a low detection limit of 189 ppb, and a strong nonlinear calibration fit (R2 = 0.9903). It achieves a response time of 90 s and recovery time of 137 s at 3 ppm isoprene, along with excellent selectivity-demonstrating 3-10 times higher response to isoprene compared to other VOCs. Additionally, it shows robust environmental stability and long-term repeatability under ambient conditions. This work contributes a low-power, scalable sensing strategy with potential for wearable, non-invasive health monitoring.
Zitieren
APA
Lu, T., You, S., Shi, G., Lyu, A., Chihi, I., & Kanoun, O. (2025). In-situ laser reduced LrGO-SnO2 chemoresistive sensor for highly selective and room-temperature isoprene detection. tm - Technisches Messen, 92(s1), 43-49. https://doi.org/10.1515/teme-2025-0053
Vancouver
Lu T, You S, Shi G, Lyu A, Chihi I, Kanoun O. In-situ laser reduced LrGO-SnO2 chemoresistive sensor for highly selective and room-temperature isoprene detection. tm - Technisches Messen. 2025;92(s1):43-49. doi:10.1515/teme-2025-0053
BibTeX
@article{Lu2025,
author = {Lu, Tianqi and You, Shiqi and Shi, Ge and Lyu, Ankang and Chihi, Ines and Kanoun, Olfa},
title = {In-situ laser reduced LrGO-SnO2 chemoresistive sensor for highly selective and room-temperature isoprene detection},
journal = {tm - Technisches Messen},
year = {2025},
volume = {92},
number = {s1},
pages = {43--49},
doi = {10.1515/teme-2025-0053}
}
EUVIMED