Could Ergonomics of Portable Oxygen Cylinders Prevent Wastage? Comparison of Two Delivery Devices

Elsa Bodier-Montagutelli, Antonin Maréchal, Richard Porcher, Francis Remérand, Renaud Respaud

Pharmaceutical Technology in Hospital Pharmacy · 2016

DOI: 10.1515/pthp-2016-0005 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pharmaceutical Technology in Hospital Pharmacy, 2016. Verfasst von Elsa Bodier-Montagutelli und 4 weiteren Autor:innen. Die Arbeit nennt 10 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Ambulatory oxygen therapy is sometimes needed when transferring inpatients. The prescribed administration rate must be maintained during the entire transit time. This implies that paramedical staff calculates the volume of gas remaining in the cylinder, based on the residual pressure displayed on the oxygen cylinders. This step carries a risk of errors and wastage. The objective of this study was to assess the impact of a digital autonomy display system on the use of oxygen cylinders at the hospital. : Two B5 oxygen cylinders (Air Liquide Santé France) were compared: Presence™ (regular manometer) and Takeo™ (digital display). This study was carried out in two wards; Presence™ cylinders were supplied for two months, and then Takeo™ cylinders for the next two months. For each period, we measured the turnover rates of the cylinders and their residual pressure. The economic impact of this change in practice was estimated by a cost study. : Use of Takeo™ cylinders resulted in a significant decrease in the turnover rate (69 % vs. 93 %, : A digital autonomy display increases the delivery performance of portable medicinal oxygen cylinders and generates an economic gain.

Zitieren

APA

Bodier-Montagutelli, E., Maréchal, A., Porcher, R., Remérand, F., & Respaud, R. (2016). Could Ergonomics of Portable Oxygen Cylinders Prevent Wastage? Comparison of Two Delivery Devices. Pharmaceutical Technology in Hospital Pharmacy. https://doi.org/10.1515/pthp-2016-0005

Vancouver

Bodier-Montagutelli E, Maréchal A, Porcher R, Remérand F, Respaud R. Could Ergonomics of Portable Oxygen Cylinders Prevent Wastage? Comparison of Two Delivery Devices. Pharmaceutical Technology in Hospital Pharmacy. 2016. doi:10.1515/pthp-2016-0005

BibTeX
@article{BodierMontagutelli2016,
  author = {Bodier-Montagutelli, Elsa and Maréchal, Antonin and Porcher, Richard and Remérand, Francis and Respaud, Renaud},
  title = {Could Ergonomics of Portable Oxygen Cylinders Prevent Wastage? Comparison of Two Delivery Devices},
  journal = {Pharmaceutical Technology in Hospital Pharmacy},
  year = {2016},
  doi = {10.1515/pthp-2016-0005}
}
Kostenlos starten →