Kapilläre Blutbildanalysen in der klinischen Praxis: eine sichere, zuverlässige und valide Methode / Capillary blood count analyses in clinical practice: a safe, reliable and valid method
LaboratoriumsMedizin · 2009-09 · 33 (5) · 303-309
DOI: 10.1515/jlm.2009.051 ↗Kurz gefasst
Fachartikel in der Zeitschrift LaboratoriumsMedizin, 2009-09. Verfasst von Enrico Schalk und 2 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 23 Literaturangaben.
Abstract (Originalsprache)
In haematology, blood count analyses are often performed on samples obtained by capillary puncture. However, only venous values are well accepted. This paper reviews the data available and highlights this topic from the viewpoint of laboratory medicine and clinical practice. We also present our own data. Mean capillary-venous differences were +0.3 g/dL or +0.2 mmol/L (+2.1%) for haemoglobin, +1.5% or +0.02 L/L (+3.6%) for haematocrit, +0.2×10 3 /μL (+2.7%) for white blood cells, +0.22×10 3 /μL (+4.7%) for absolute neutrophil counts, –19×10 3 /μL (–8.3%) for platelets and +0.1×10 6 /μL (+1.8%) for red blood cells. Differences were greater in children than in adults: +1.1 g/dL or +0.7 mmol/L (+6.3%) for haemoglobin, +3.1% or +0.03 L/L (+6.0%) for haematocrit, +2.0×10 3 /μL (+14.6%) for white blood cells, +0.91×10 3 /μL (+11.0%) for absolute neutrophil counts, –33×10 3 /μL (–14.1%) for platelets and +0.3×10 6 /μL (+6.0%) for red blood cells. The capillary values correlated very well with the venous values. Capillary blood count analysis is safe, reliable and advantageous compared to venous analysis and has high probability for true -positive and true -negative values for patients with anaemia, polyglobulia, thrombocytopenia and neutrocytopenia in comparison to venous blood count analysis. Therefore, at least in adults, capillary blood count analysis can be used as a substitute for venous blood count analysis in clinical practice.
Zitieren
APA
Schalk, E., Scheinpflug, K., & Mohren, M. (2009). Kapilläre Blutbildanalysen in der klinischen Praxis: eine sichere, zuverlässige und valide Methode / Capillary blood count analyses in clinical practice: a safe, reliable and valid method. LaboratoriumsMedizin, 33(5), 303-309. https://doi.org/10.1515/jlm.2009.051
Vancouver
Schalk E, Scheinpflug K, Mohren M. Kapilläre Blutbildanalysen in der klinischen Praxis: eine sichere, zuverlässige und valide Methode / Capillary blood count analyses in clinical practice: a safe, reliable and valid method. LaboratoriumsMedizin. 2009;33(5):303-309. doi:10.1515/jlm.2009.051
BibTeX
@article{Schalk2009,
author = {Schalk, Enrico and Scheinpflug, Katrin and Mohren, Martin},
title = {Kapilläre Blutbildanalysen in der klinischen Praxis: eine sichere, zuverlässige und valide Methode / Capillary blood count analyses in clinical practice: a safe, reliable and valid method},
journal = {LaboratoriumsMedizin},
year = {2009},
volume = {33},
number = {5},
pages = {303--309},
doi = {10.1515/jlm.2009.051}
}
EUVIMED