Evaluation of the analytical performance and usability of the VChemy S analyzer for decentralized multipanel testing

Nerea Varo iD, Maialen Palomino, Victoria Hauke, Carmen Mugueta, María Gil-Rodríguez, José Vicente García-Villalobos, María Blázquez-Rodríguez, Débora Martínez-Espartosa iD, Álvaro González

Diagnosis · 21.05.2026

DOI: 10.1515/dx-2026-0035 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diagnosis, online erschienen am 21.05.2026. Verfasst von Nerea Varo und 8 weiteren Autor:innen. Beteiligte Einrichtung: Biochemistry Service, Clínica Universidad de Navarra, Pamplona, Spain. Die Arbeit nennt 26 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To evaluate the analytical performance, comparability, reference interval transference, and usability of the VChemy S point-of-care testing (POCT) analyzer for 16 biochemistry analytes using whole blood, serum and plasma. The study aimed to determine its suitability for decentralized testing and concordance with accredited central laboratory methods.

Methods

Adult outpatients were recruited to assess precision following CLSI EP15 and method comparison following CLSI EP09. Measurements were performed using VChemy S cartridges in whole blood, serum, and plasma and compared with results obtained in Roche Cobas ® Pro. Analytical performance was evaluated through Passing-Bablok regression, Bland-Altman analysis and comparison with EFLM minimum analytical quality specifications. Reference interval transference was examined according to CLSI EP28 using healthy volunteers. Usability was assessed through a 15-item Likert-scale questionnaire completed by users.

Results

All analytes showed acceptable repeatability and within-laboratory imprecision, meeting manufacturer specifications and EFLM analytical performance targets, except glucose, which exceeded its APS. Fourteen of the sixteen analytes demonstrated analytical comparability across all matrices, with mean relative differences within total allowable error. Chloride and alkaline phosphatase exhibited method-dependent biases, preventing interchangeability and reference interval transference for chloride. Reference intervals were verified for all remaining analytes. Usability evaluation demonstrated a high satisfaction score (above 90 %).

Conclusions

VChemy S provides analytically reliable results in whole blood, serum, and plasma for most routine biochemistry analytes, demonstrating strong alignment with central laboratory methods. Its portability, concordance with central laboratory methods, and user acceptance support its implementation in decentralized clinical settings, enabling faster decision-making and reduced preanalytical complexity.

Schlagwörter

Stichwörter der Autor:innen

decentralized testingmatricesmethod comparisonpoint of care testing

Autor:innen und Institutionen

  • Biochemistry Service, Clínica Universidad de Navarra, Pamplona, Spain.
  • IdiSNA, Navarra Institute for Health Research, Pamplona, Spain.
  • Universidad de Navarra, Pamplona, Spain.
  • Biochemistry Service, Clínica Universidad de Navarra, Madrid, Spain.
  • Service of Biochemistry, Cancer Center Clínica Universidad de Navarra, Pamplona, Spain.

ORCID-Profile: Nerea Varo, Débora Martínez-Espartosa

Zitieren

APA

Varo, N., Palomino, M., Hauke, V., Mugueta, C., Gil-Rodríguez, M., García-Villalobos, J. V., Blázquez-Rodríguez, M., Martínez-Espartosa, D., & González, Á. (2026). Evaluation of the analytical performance and usability of the VChemy S analyzer for decentralized multipanel testing. Diagnosis. https://doi.org/10.1515/dx-2026-0035

Vancouver

Varo N, Palomino M, Hauke V, Mugueta C, Gil-Rodríguez M, García-Villalobos JV, et al. Evaluation of the analytical performance and usability of the VChemy S analyzer for decentralized multipanel testing. Diagnosis. 2026. doi:10.1515/dx-2026-0035

BibTeX
@article{Varo2026,
  author = {Varo, Nerea and Palomino, Maialen and Hauke, Victoria and Mugueta, Carmen and Gil-Rodríguez, María and García-Villalobos, José Vicente and Blázquez-Rodríguez, María and Martínez-Espartosa, Débora and González, Álvaro},
  title = {Evaluation of the analytical performance and usability of the VChemy S analyzer for decentralized multipanel testing},
  journal = {Diagnosis},
  year = {2026},
  doi = {10.1515/dx-2026-0035}
}
Kostenlos starten →