EUVIMEDEUVIMED entdecken
Crossref

Diagnostic accuracy of non-mydriatic fundus photography as a triage and telemedicine tool for patients with vision loss

Chijindu A Ukagwu iD, Joshua C Teichman, Amandeep S Rai, Amrit S Rai, Gary L Yau, Michelle Khan, Rahul A Sharma

Diagnosis · 2025

DOI: 10.1515/dx-2024-0199 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diagnosis, 2025. Verfasst von Chijindu A Ukagwu und 6 weiteren Autor:innen. Beteiligte Einrichtung: Temerty Faculty of Medicine, University of Toronto, Toronto, Canada. Hauptthemen laut MEDLINE: Triage, Photography, Fundus Oculi, Vision Disorders. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 19 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Fundoscopy can be challenging for non-ophthalmologists. For emergency physicians, non-mydriatic fundus photography is superior to other forms of ophthalmoscopy in sensitivity, specificity, and inter-examination agreement. We report on a prospective cross-sectional study evaluating the use of non-mydriatic photography as a triage and telemedicine tool for patients with vision loss in a Canadian emergency setting.

Methods

Images of both eyes were obtained by a non-ophthalmologist using a handheld, non-mydriatic fundus camera and shared with a fellowship-trained ophthalmologist without patient context. The reviewer was asked to (1) select the best photo obtained for each eye and rate image quality on a Likert scale, (2) comment on the presence or absence of fundus abnormalities and (3) provide an opinion on whether findings would have changed patient disposition if available at the time of the initial Emergency Department (ED) exam.

Results

Of 57 patients evaluated in the ED for vision loss, 22.8 % had a documented fundus examination. 86.8 % of images were deemed to have acceptable quality (Likert scale≥2). Factors limiting image quality included media opacity, pupillary miosis, photosensitivity, and eyelid/periorbital abnormalities. Of patients with relevant abnormalities, 0 % were identified by emergency physicians. In contrast, 37.5 % of patients with relevant findings were identified on review of images alone (specificity=100 %).

Conclusions

Fundoscopy is infrequently performed in the emergency setting in patients presenting with vision loss. Non-mydriatic fundus photography is a cost-effective method of fundus examination for non-expert examiners and can be reliably used as a telemedicine tool for remote ophthalmology consultation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TriagePhotographyFundus OculiVision DisordersHumansTelemedicineCross-Sectional StudiesProspective StudiesFemaleMiddle AgedMaleAdultAgedOphthalmoscopyEmergency Service, HospitalSensitivity and SpecificityAged, 80 and overCanada

Stichwörter der Autor:innen

emergency medicinefundoscopynon-mydriatic photographyphysician documentationtelemedicinevision loss

Autor:innen und Institutionen

  • Temerty Faculty of Medicine, University of Toronto, Toronto, Canada.
  • Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, Canada.

ORCID-Profile: Chijindu A Ukagwu

Zitieren

APA

Ukagwu, C. A., Teichman, J. C., Rai, A. S., Rai, A. S., Yau, G. L., Khan, M., & Sharma, R. A. (2025). Diagnostic accuracy of non-mydriatic fundus photography as a triage and telemedicine tool for patients with vision loss. Diagnosis. https://doi.org/10.1515/dx-2024-0199

Vancouver

Ukagwu CA, Teichman JC, Rai AS, Rai AS, Yau GL, Khan M, et al. Diagnostic accuracy of non-mydriatic fundus photography as a triage and telemedicine tool for patients with vision loss. Diagnosis. 2025. doi:10.1515/dx-2024-0199

BibTeX
@article{Ukagwu2025,
  author = {Ukagwu, Chijindu A and Teichman, Joshua C and Rai, Amandeep S and Rai, Amrit S and Yau, Gary L and Khan, Michelle and Sharma, Rahul A},
  title = {Diagnostic accuracy of non-mydriatic fundus photography as a triage and telemedicine tool for patients with vision loss},
  journal = {Diagnosis},
  year = {2025},
  doi = {10.1515/dx-2024-0199}
}