EUVIMEDEUVIMED entdecken
Crossref

Addressing property and unit discordance in laboratory interoperability: the role of NPU as a governance layer

Kuenyoul Park iD, Sollip Kim, Tony Badrick iD, Madeleen Bosma, Suhas Chaudhari, Fatma Meriç Yılmaz, Koh Furuta iD, Gunnar Nordin, Young Bae Lee Hansen iD

Clinical Chemistry and Laboratory Medicine (CCLM) · 25.11.2026 · 64 (12) · 2683-2695

DOI: 10.1515/cclm-2026-0743 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Chemistry and Laboratory Medicine (CCLM), online erschienen am 06.07.2026. Verfasst von Kuenyoul Park und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Laboratory Medicine, Hanyang University Seoul Hospital, Hanyang University College of Medicine, Seoul, South Korea. Hauptthemen laut MEDLINE: Terminology as Topic, Laboratories, Clinical. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 28 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Unified Code for Units of Measure (UCUM) encodes syntax without prescribing which unit should be used. The Nomenclature for Properties and Units (NPU) terminology, developed by IFCC and IUPAC, specifies both the kind-of-quantity (e.g., mass concentration or substance concentration) and the recommended unit for each code, and can serve as a governance layer, yet no study has evaluated how NPU-recommended units align with actual laboratory practice.

Methods

30 clinical chemistry measurands in blood were selected from the overlap between a Korean multi-institutional unit-usage survey and a consensus study on commonly tested analytes mapped to LOINC. For each measurand, commonly used units in Korean laboratories, RCPA-recommended units, and NPU-recommended units were compared, along with LOINC example units.

Results

Of the 30 measurands, 6 (20 %) were fully concordant across Korean practice, Australian practice, and NPU. For 15 (50 %), a kind-of-quantity discordance was observed: Korean laboratories reported mass concentration (mg/dL), whereas Australian practice and NPU used substance concentration (mmol/L). For 6 (20 %), Korean laboratories used IU/L while Australian practice and NPU used U/L. Korean and Australian LOINC code selections overlapped for only 15 (50 %), reflecting different national choices of kind-of-quantity; Korean practice uniformly matched LOINC example units, whereas Australian practice deviated in three instances. NPU did not provide mass concentration codes for the 15 discordant measurands that are reported in mass concentration units in Korea.

Conclusions

The predominant discordance reflects a lack of international agreement on kind-of-quantity selection. A stepwise transition strategy – from unit symbol correction to kind-of-quantity transition – can be informed by the degree of discordance.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Terminology as TopicLaboratories, ClinicalHumansRepublic of KoreaAustralia

Stichwörter der Autor:innen

HbA1cLOINCNPU terminologySI unitssemantic interoperabilityunit harmonization

Autor:innen und Institutionen

  • Department of Laboratory Medicine, Hanyang University Seoul Hospital, Hanyang University College of Medicine, Seoul, South Korea.
  • Department of Laboratory Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea.
  • Institute of Digital Healthcare, University of Ulsan College of Medicine, Seoul, South Korea.
  • Royal College of Pathologists of Australasia Quality Assurance Programs, St Leonards, NSW, Australia.
  • Biomedical Science, Faculty of Medicine, Bond University, Gold Coast, Australia.
  • Department of Clinical Chemistry and Laboratory Medicine, Leiden University Medical Center, Leiden, The Netherlands.

ORCID-Profile: Kuenyoul Park, Tony Badrick, Koh Furuta, Young Bae Lee Hansen

Zitieren

APA

Park, K., Kim, S., Badrick, T., Bosma, M., Chaudhari, S., Yılmaz, F. M., Furuta, K., Nordin, G., & Hansen, Y. B. L. (2026). Addressing property and unit discordance in laboratory interoperability: the role of NPU as a governance layer. Clinical Chemistry and Laboratory Medicine (CCLM), 64(12), 2683-2695. https://doi.org/10.1515/cclm-2026-0743

Vancouver

Park K, Kim S, Badrick T, Bosma M, Chaudhari S, Yılmaz FM, et al. Addressing property and unit discordance in laboratory interoperability: the role of NPU as a governance layer. Clinical Chemistry and Laboratory Medicine (CCLM). 2026;64(12):2683-2695. doi:10.1515/cclm-2026-0743

BibTeX
@article{Park2026,
  author = {Park, Kuenyoul and Kim, Sollip and Badrick, Tony and Bosma, Madeleen and Chaudhari, Suhas and Yılmaz, Fatma Meriç and Furuta, Koh and Nordin, Gunnar and Hansen, Young Bae Lee},
  title = {Addressing property and unit discordance in laboratory interoperability: the role of NPU as a governance layer},
  journal = {Clinical Chemistry and Laboratory Medicine (CCLM)},
  year = {2026},
  volume = {64},
  number = {12},
  pages = {2683--2695},
  doi = {10.1515/cclm-2026-0743}
}
Kostenlos starten →