EUVIMEDEUVIMED entdecken
Vergleichsstudie

Comparison of CD34-positive cells enumeration using ADAMII image-based fluorescence cell counter with fluorescence flow cytometry

Joan Cid iD, Paola Charry iD, María Dolores Herrera, Íngrid Cardona, Elisenda Soler, Núria Monfort, Miquel Lozano iD

Clinical Chemistry and Laboratory Medicine (CCLM) · 2026

DOI: 10.1515/cclm-2026-0474 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Clinical Chemistry and Laboratory Medicine (CCLM), 2026. Verfasst von Joan Cid und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Hemotherapy and Hemostasis, ICAMS, Clínic Barcelona, Barcelona, Spain. Hauptthemen laut MEDLINE: Flow Cytometry, Antigens, CD34. Die Arbeit nennt 16 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

The gold standard method of CD34+ cells counting is based on fluorescence flow cytometry. Previous studies showed that image-based immunofluorescence cell counting could be suitable for enumerating CD34+ cells. We compared CD34+ cell counting with both methods using samples obtained from mobilized peripheral blood (MPB) and leukapheresis bags (LB).

Methods

Samples were obtained from MPB (n=74) and LBs (n=41). Flow cytometry CD34+ cell enumeration was performed according to the ISHAGE single-platform protocol. CD34+ cell enumeration with ADAMII device was performed following manufacturer’s instructions. Spearman rank correlation coefficient (r s ) and bias study were performed. Bland–Altman analysis was performed to plot the bias.

Results

A statistically significant strong positive linear correlation was observed between both methods (r s >0.9 and p

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Flow CytometryAntigens, CD34HumansCell CountFluorescence

Stichwörter der Autor:innen

antigens CD34blood cell countflow cytometryimage-based fluorescence cell counter

Substanzen

Antigens, CD34

Autor:innen und Institutionen

  • Department of Hemotherapy and Hemostasis, ICAMS, Clínic Barcelona, Barcelona, Spain.
  • IDIBAPS, Barcelona, Spain.
  • University of Barcelona, Barcelona, Spain.

ORCID-Profile: Joan Cid, Paola Charry, Miquel Lozano

Zitieren

APA

Cid, J., Charry, P., Herrera, M. D., Cardona, Í., Soler, E., Monfort, N., & Lozano, M. (2026). Comparison of CD34-positive cells enumeration using ADAMII image-based fluorescence cell counter with fluorescence flow cytometry. Clinical Chemistry and Laboratory Medicine (CCLM). https://doi.org/10.1515/cclm-2026-0474

Vancouver

Cid J, Charry P, Herrera MD, Cardona Í, Soler E, Monfort N, et al. Comparison of CD34-positive cells enumeration using ADAMII image-based fluorescence cell counter with fluorescence flow cytometry. Clinical Chemistry and Laboratory Medicine (CCLM). 2026. doi:10.1515/cclm-2026-0474

BibTeX
@article{Cid2026,
  author = {Cid, Joan and Charry, Paola and Herrera, María Dolores and Cardona, Íngrid and Soler, Elisenda and Monfort, Núria and Lozano, Miquel},
  title = {Comparison of CD34-positive cells enumeration using ADAMII image-based fluorescence cell counter with fluorescence flow cytometry},
  journal = {Clinical Chemistry and Laboratory Medicine (CCLM)},
  year = {2026},
  doi = {10.1515/cclm-2026-0474}
}
Kostenlos starten →