Evaluating the performance of a multiparametric IgA assay for celiac disease diagnosis
Clinical Chemistry and Laboratory Medicine (CCLM) · 2025
DOI: 10.1515/cclm-2025-0705 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Chemistry and Laboratory Medicine (CCLM), 2025. Verfasst von Caterina Maria Gambino und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedicine, Neurosciences and Advanced Diagnostics, Institute of Clinical Biochemistry, Clinical Molecular Medicine, and Clinical Labo…. Hauptthemen laut MEDLINE: Celiac Disease, Immunoglobulin A. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 40 Literaturangaben.
Abstract (Originalsprache)
Objectives
Celiac disease (CD) is a systemic autoimmune disorder triggered by gluten in genetically predisposed individuals. Accurate diagnosis remains challenging due to clinical heterogeneity and reliance on invasive biopsy. This study aimed to evaluate the diagnostic performance of a novel multiparametric membrane-based enzyme immunoassay (AESKUBLOTS ® ) for the simultaneous detection of IgA antibodies targeting eight CD-related antigens.
Methods
A retrospective, single-centre study was conducted on 180 participants: 80 with CD (30 untreated, 50 on gluten-free diet, GFD), 50 with non-celiac wheat sensitivity (NCWS), and 50 healthy controls (HC). Serum samples were analysed using the AESKU assay. Diagnostic accuracy was assessed via ROC curve analysis and 5-fold cross-validation, examining individual markers and a composite antibody score.
Results
The assay demonstrated high diagnostic performance, particularly in untreated CD patients. Anti-tTG neo IgA showed the highest accuracy (AUC=0.93), followed by anti-tTG IgA (AUC=0.92). A composite score of ≥4 positive markers yielded an AUC of 0.99, while ≥6 positive markers achieved 100 % specificity and PPV, with 76.7 % sensitivity. Notably, anti-mTG IgA levels were elevated in all CD patients regardless of diet, suggesting potential utility in monitoring or identifying ongoing mucosal immune activity.
Conclusions
This multiparametric IgA assay offers a sensitive, specific, and non-invasive diagnostic tool for CD. Larger, prospective studies are warranted to confirm the clinical utility and expand the applicability to broader populations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Biomedicine, Neurosciences and Advanced Diagnostics, Institute of Clinical Biochemistry, Clinical Molecular Medicine, and Clinical Laboratory Medicine, University of Palermo, Palermo, Italy.
- Department of Laboratory Medicine, University Hospital Paolo Giaccone, Palermo, Italy.
- Immunopathology and Cancer Biomarkers, Centro di Riferimento Oncologico (CRO)-IRCCS, Aviano, Italy.
- Department of Health Promotion, Maternal and Infant Care, Internal Medicine and Medical Specialties "G. D'Alessandro", University of Palermo, Palermo, Italy.
ORCID-Profile: Fabio Del Ben
Zitieren
APA
Gambino, C. M., Agnello, L., Del Ben, F., Ciaccio, A. M., Milano, S., Vassallo, R., Cacciabaudo, F., Seidita, A., Mansueto, P., Carroccio, A., & Ciaccio, M. (2025). Evaluating the performance of a multiparametric IgA assay for celiac disease diagnosis. Clinical Chemistry and Laboratory Medicine (CCLM). https://doi.org/10.1515/cclm-2025-0705
Vancouver
Gambino CM, Agnello L, Del Ben F, Ciaccio AM, Milano S, Vassallo R, et al. Evaluating the performance of a multiparametric IgA assay for celiac disease diagnosis. Clinical Chemistry and Laboratory Medicine (CCLM). 2025. doi:10.1515/cclm-2025-0705
BibTeX
@article{Gambino2025,
author = {Gambino, Caterina Maria and Agnello, Luisa and Del Ben, Fabio and Ciaccio, Anna Maria and Milano, Salvatore and Vassallo, Roberta and Cacciabaudo, Francesco and Seidita, Aurelio and Mansueto, Pasquale and Carroccio, Antonio and Ciaccio, Marcello},
title = {Evaluating the performance of a multiparametric IgA assay for celiac disease diagnosis},
journal = {Clinical Chemistry and Laboratory Medicine (CCLM)},
year = {2025},
doi = {10.1515/cclm-2025-0705}
}
EUVIMED