Fachartikel in der Zeitschrift Clinical Chemistry and Laboratory Medicine (CCLM), 2025. Verfasst von Tobias Schierscher und 10 weiteren Autor:innen. Beteiligte Einrichtung: Dr. Risch Ostschweiz AG, Buchs, Switzerland. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Mycophenolic Acid, Blood Chemical Analysis. Die Arbeit nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objectives
A candidate reference measurement procedure (RMP) based on isotope dilution (ID) liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed and validated to accurately measure serum and plasma concentrations of mycophenolic acid (MPA).
Methods
Quantitative nuclear magnetic resonance (qNMR) spectroscopy was utilized for determining the absolute content of the reference material, guaranteeing its traceability to SI units. Separation of MPA from potential interferences, whether known or unknown, was accomplished by using a C18 column. For sample preparation, a protocol for protein precipitation followed by a high dilution step was established. Assay validation and measurement uncertainty determination were conducted following the Clinical and Laboratory Standards Institute, the International Conference on Harmonization, and the Guide to the Expression of Uncertainty in Measurement guidelines.
Results
The RMP demonstrated high selectivity and specificity without any indication of a matrix effect, enabling the quantification of MPA in the range between 0.240 and 18.0 mg/L. The intermediate precision and repeatability (n=60, measurements) were found to be
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Dr. Risch Ostschweiz AG, Buchs, Switzerland.
- 111618 Roche Diagnostics GmbH , Penzberg, Germany.
- Chrestos Concept GmbH & Co. KG, Essen, Germany.
ORCID-Profile: Lorenz Risch
Zitieren
APA
Schierscher, T., Salzmann, L., Singh, N., Schäfer, C., Sungauer, L., Bauland, F., Geistanger, A., Risch, L., Geletneky, C., Seger, C., & Taibon, J. (2025). An isotope dilution-liquid-chromatography-tandem mass spectrometry-based candidate reference measurement procedure for the quantification of mycophenolic acid in human serum and plasma. Clinical Chemistry and Laboratory Medicine (CCLM). https://doi.org/10.1515/cclm-2024-0860
Vancouver
Schierscher T, Salzmann L, Singh N, Schäfer C, Sungauer L, Bauland F, et al. An isotope dilution-liquid-chromatography-tandem mass spectrometry-based candidate reference measurement procedure for the quantification of mycophenolic acid in human serum and plasma. Clinical Chemistry and Laboratory Medicine (CCLM). 2025. doi:10.1515/cclm-2024-0860
BibTeX
@article{Schierscher2025,
author = {Schierscher, Tobias and Salzmann, Linda and Singh, Neeraj and Schäfer, Carina and Sungauer, Luc and Bauland, Friederike and Geistanger, Andrea and Risch, Lorenz and Geletneky, Christian and Seger, Christoph and Taibon, Judith},
title = {An isotope dilution-liquid-chromatography-tandem mass spectrometry-based candidate reference measurement procedure for the quantification of mycophenolic acid in human serum and plasma},
journal = {Clinical Chemistry and Laboratory Medicine (CCLM)},
year = {2025},
doi = {10.1515/cclm-2024-0860}
}
EUVIMED