RetinalFRNet: retinal vessel segmentation in OCTA images using the feature reconstruction network
Biomedical Engineering / Biomedizinische Technik · 2026
DOI: 10.1515/bmt-2026-0107 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomedical Engineering / Biomedizinische Technik, 2026. Verfasst von Tingting Wang und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, The Second Affiliated Hospital of Anhui Medical University, Hefei, China. Hauptthemen laut MEDLINE: Retinal Vessels, Tomography, Optical Coherence, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objectives
Automated segmentation of retinal blood vessels in optical coherence tomography angiography (OCTA) images is essential for early diagnosis of ocular diseases such as diabetic retinopathy, myopia, and macular degeneration. This study evaluates the performance of the Retinal Feature Reconstruction Network (RetinalFRNet), a full-resolution deep learning architecture designed for OCTA retinal vessel segmentation.
Methods
RetinalFRNet integrates recurrent neural network modules within a ConvNeXt backbone while preserving full spatial resolution without downsampling. Its performance was compared with five algorithms – fuzzy C-means (FCM), U-Net, ResUnet, Vision Transformer (ViT), and VM-Unet – using three publicly available datasets (OCTA-3 mm, OCTA-6 mm, and ROSSA). All models were trained using the Adam optimizer for 100 epochs and evaluated using seven standard metrics including Accuracy, Dice coefficient, Sensitivity, and mean Intersection over Union (IoU).
Results
RetinalFRNet achieved the highest overall performance across all datasets, reaching a Dice coefficient of 91.72 % and mean IoU of 84.93 % on the ROSSA dataset, improving performance by up to 30.66 % over the FCM baseline.
Conclusions
RetinalFRNet demonstrates superior accuracy and robustness for OCTA retinal vessel segmentation. Its downsampling-free architecture enables improved detection of fine vascular structures critical for ophthalmic diagnosis. Further multi-center validation is recommended prior to clinical deployment.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ophthalmology, The Second Affiliated Hospital of Anhui Medical University, Hefei, China.
- Hefei Purui Eye Hospital, Hefei, China.
Zitieren
APA
Wang, T., & Xu, Y. (2026). RetinalFRNet: retinal vessel segmentation in OCTA images using the feature reconstruction network. Biomedical Engineering / Biomedizinische Technik. https://doi.org/10.1515/bmt-2026-0107
Vancouver
Wang T, Xu Y. RetinalFRNet: retinal vessel segmentation in OCTA images using the feature reconstruction network. Biomedical Engineering / Biomedizinische Technik. 2026. doi:10.1515/bmt-2026-0107
BibTeX
@article{Wang2026,
author = {Wang, Tingting and Xu, Yuxin},
title = {RetinalFRNet: retinal vessel segmentation in OCTA images using the feature reconstruction network},
journal = {Biomedical Engineering / Biomedizinische Technik},
year = {2026},
doi = {10.1515/bmt-2026-0107}
}
EUVIMED