EUVIMEDEUVIMED entdecken
Crossref

A new method for vital sign detection using FMCW radar based on random body motion cancellation

Shuai Fu, Ming Ling, Zhenhua Li, Long Pan

Biomedical Engineering / Biomedizinische Technik · 2023

DOI: 10.1515/bmt-2023-0068 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Engineering / Biomedizinische Technik, 2023. Verfasst von Shuai Fu und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Electronic and Electrical Engineering, Shanghai University of Engineering Science, ShangHai, China. Hauptthemen laut MEDLINE: Signal Processing, Computer-Assisted, Radar. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 57 Literaturangaben. Gefördert von: Shanghai Technology Innovation Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this study, we present a new method for acquiring human vital signs using a Range-Doppler matrix (RDM) of FMCW radar data and a Gaussian interpolation algorithm (GIA). First, the RDM is derived by applying a two-dimensional fast Fourier transform (2D-FFT) to the radar data, and the GIA is applied in the Doppler dimension to estimate the target velocity signal. Subsequently, a robust enhanced trend filtering (RETF) algorithm is used to eliminate the large-scale body motion from the vital signs. Finally, the time-varying filter-based empirical mode decomposition (TVF-EMD) algorithm is employed to extract the respiratory and heartbeat intrinsic mode functions (IMFs), which are filtered according to their respective spectral power to obtain the respiratory and heartbeat frequencies. The proposed method was evaluated using vital signs data collected from seven volunteers (4 males and 3 females) with Texas Instrument’s AWR1642, and the results were compared with data from a reference monitor. The experiments showed that the method had an accuracy of 93 % for respiration and 95 % for heart rate in the presence of random body movements. Unlike traditional radar-based vital signs detection methods, this approach does not rely on range bin selection of the range profile matrix (RPM), thereby avoiding phase wrap problems and producing more accurate results. Currently, research in this field is limited.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Signal Processing, Computer-AssistedRadarMaleFemaleHumansVital SignsHeart RateRespiratory RateAlgorithms

Stichwörter der Autor:innen

Gaussian interpolationempirical mode decompositionrandom body motiontrend filteringvital signs

Autor:innen und Institutionen

  • School of Electronic and Electrical Engineering, Shanghai University of Engineering Science, ShangHai, China.
  • Shanghai Baolong Automotive Corporation, ShangHai, China.

Förderung

  • Shanghai Technology Innovation Project

Zitieren

APA

Fu, S., Ling, M., Li, Z., & Pan, L. (2023). A new method for vital sign detection using FMCW radar based on random body motion cancellation. Biomedical Engineering / Biomedizinische Technik. https://doi.org/10.1515/bmt-2023-0068

Vancouver

Fu S, Ling M, Li Z, Pan L. A new method for vital sign detection using FMCW radar based on random body motion cancellation. Biomedical Engineering / Biomedizinische Technik. 2023. doi:10.1515/bmt-2023-0068

BibTeX
@article{Fu2023,
  author = {Fu, Shuai and Ling, Ming and Li, Zhenhua and Pan, Long},
  title = {A new method for vital sign detection using FMCW radar based on random body motion cancellation},
  journal = {Biomedical Engineering / Biomedizinische Technik},
  year = {2023},
  doi = {10.1515/bmt-2023-0068}
}
Kostenlos starten →