EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Washing-dependent antistatic performance of antimicrobially finished woven polyester fabric for textile air distribution systems

Rasa Gofman, Sandra Varnaitė – Žuravliova, Rimvydas Milašius

AUTEX Research Journal · 23.01.2026 · 26 (1)

DOI: 10.1515/aut-2025-0079 ↗

Kurz gefasst

Fachartikel in der Zeitschrift AUTEX Research Journal, online erschienen am 13.07.2026. Verfasst von Rasa Gofman und 2 weiteren Autor:innen. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Kaunas University of Technology.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In textile air distribution systems, functional properties such as antimicrobial and antistatic performance are typically introduced into the fabric through separate methods. In this study, a novel silica-based benzalkonium chloride (BAC) finish, originally developed for antimicrobial performance, was further evaluated for its secondary antistatic effect (earlier detected by the authors) on woven 100 % polyester fabric after 0, 1, 2, 5, and 10 washing cycles. The unwashed finished fabric exhibited acceptable antistatic properties according to the requirements for protective clothing. FTIR analysis confirmed the presence of silica and BAC on the finished fabric sample surface. However, the antistatic effect progressively declined with washing, with surface resistivity approaching that of the unfinished fabric. FTIR band intensities characteristic of silica and BAC decreased in washed finished fabric samples, confirming a partial wash-out of both components from the fabric surface. Since silica nanoparticles are electrical insulators, the observed antistatic effect is more likely attributable to BAC. A single finish Integrating both antimicrobial and antistatic properties into a 100 % polyester fabric with one finishing may facilitate end-of-life recycling and improve the sustainability profile of fabrics for textile air distribution systems.

Förderung

  • Kaunas University of Technology

Zitieren

APA

Gofman, R., Žuravliova, S. V., & Milašius, R. (2026). Washing-dependent antistatic performance of antimicrobially finished woven polyester fabric for textile air distribution systems. AUTEX Research Journal, 26(1). https://doi.org/10.1515/aut-2025-0079

Vancouver

Gofman R, Žuravliova SV, Milašius R. Washing-dependent antistatic performance of antimicrobially finished woven polyester fabric for textile air distribution systems. AUTEX Research Journal. 2026;26(1). doi:10.1515/aut-2025-0079

BibTeX
@article{Gofman2026,
  author = {Gofman, Rasa and Žuravliova, Sandra Varnaitė – and Milašius, Rimvydas},
  title = {Washing-dependent antistatic performance of antimicrobially finished woven polyester fabric for textile air distribution systems},
  journal = {AUTEX Research Journal},
  year = {2026},
  volume = {26},
  number = {1},
  doi = {10.1515/aut-2025-0079}
}
Kostenlos starten →