EUVIMEDEUVIMED entdecken
Video/AudioFallbericht

Alfred Kocher technique for prevention of patient–prosthesis mismatch in paediatric patients

Peter Murin, Martin Winter, Paul Werner, Erhan Urganci, Clemens Atteneder, Alexandra Andreeva, Emilio Osorio-Jaramillo, Daniel Zimpfer, Alfred Kocher

Multimedia Manual of Cardio-Thoracic Surgery · 11.11.2026

DOI: 10.1510/mmcts.2026.106 ↗

Kurz gefasst

Video/Audio in der Zeitschrift Multimedia Manual of Cardio-Thoracic Surgery, online erschienen am 11.11.2026. Verfasst von Peter Murin und 8 weiteren Autor:innen. Beteiligte Einrichtung: Congenital and Pediatric Cardiac Surgery, Department of Cardiac and Thoracic Aortic Surgery, Medical University of Vienna, Vienna, Austria. Hauptthemen laut MEDLINE: Heart Valve Prosthesis, Heart Valve Prosthesis Implantation, Aortic Valve, Heart Valve Diseases.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aortic valve replacement requires special considerations in paediatric patients, who are not yet fully grown. The Ross procedure remains the gold standard in paediatric patients as it offers growth potential. If the Ross procedure is not feasible, or the size of the aortic annulus precludes placement of an adult-sized mechanical prosthesis, the problem of patient–prosthesis mismatch and subsequent aortic valve reinterventions arises. The standardized option for this patient cohort is the Konno incision and patch ventriculoplasty in combination with an adult-sized mechanical prosthesis, which carries substantial procedural complexity and risk. This video tutorial demonstrates posterior aortic root enlargement using the Alfred Kocher technique in a 7-year-old female with a functionally unicuspid aortic valve and a bicuspid pulmonary valve. The bicuspid pulmonary valve was an unplanned intraoperative finding, making the patient ineligible for a durable autograft transplantation. The technique involves an inverted T-shaped incision in the centre of the non-coronary sinus, and reconstruction with a barrel-shaped patch tailored from a 28 mm Valsalva prosthesis to augment the non-coronary sinus in an anatomical fashion, allowing upsizing by 5 mm in annular diameter. This technique enabled implantation of a 21 mm size mechanical prosthesis (diameter = 24 mm) upsized from a 19 mm annulus.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart Valve ProsthesisHeart Valve Prosthesis ImplantationAortic ValveHeart Valve DiseasesHumansFemaleChildProsthesis DesignBicuspid Aortic Valve DiseasePulmonary Valve

Stichwörter der Autor:innen

Aortic rootAortic valve replacementCongenital aortic valve stenosis

Autor:innen und Institutionen

  • Congenital and Pediatric Cardiac Surgery, Department of Cardiac and Thoracic Aortic Surgery, Medical University of Vienna, Vienna, Austria

Zitieren

APA

Murin, P., Winter, M., Werner, P., Urganci, E., Atteneder, C., Andreeva, A., Osorio-Jaramillo, E., Zimpfer, D., & Kocher, A. (2026). Alfred Kocher technique for prevention of patient–prosthesis mismatch in paediatric patients. Multimedia Manual of Cardio-Thoracic Surgery. https://doi.org/10.1510/mmcts.2026.106

Vancouver

Murin P, Winter M, Werner P, Urganci E, Atteneder C, Andreeva A, et al. Alfred Kocher technique for prevention of patient–prosthesis mismatch in paediatric patients. Multimedia Manual of Cardio-Thoracic Surgery. 2026. doi:10.1510/mmcts.2026.106

BibTeX
@article{Murin2026,
  author = {Murin, Peter and Winter, Martin and Werner, Paul and Urganci, Erhan and Atteneder, Clemens and Andreeva, Alexandra and Osorio-Jaramillo, Emilio and Zimpfer, Daniel and Kocher, Alfred},
  title = {Alfred Kocher technique for prevention of patient–prosthesis mismatch in paediatric patients},
  journal = {Multimedia Manual of Cardio-Thoracic Surgery},
  year = {2026},
  doi = {10.1510/mmcts.2026.106}
}
Kostenlos starten →