EUVIMEDEUVIMED entdecken
Video/AudioFallbericht

Transaxillary direct-view aortic valve replacement with Intuity Elite rapid-deployment valve

Michele Galeazzi, Erlil Mali, Simone D'Alessio, Martina Giusti, Carlo Zingaro, Pietro Malvindi, Paolo Berretta, Marco Di Eusanio

Multimedia Manual of Cardio-Thoracic Surgery · 19.11.2026

DOI: 10.1510/mmcts.2026.101 ↗

Kurz gefasst

Video/Audio in der Zeitschrift Multimedia Manual of Cardio-Thoracic Surgery, online erschienen am 19.11.2026. Verfasst von Michele Galeazzi und 7 weiteren Autor:innen. Beteiligte Einrichtung: Cardiac Surgery Department, Lancisi Cardiovascular Center – OORR, Minimally Invasive and Trans Catheter Cardiac Surgery Research Center, Polytechnic …. Hauptthemen laut MEDLINE: Heart Valve Prosthesis Implantation, Aortic Valve, Thoracotomy, Heart Valve Prosthesis.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

We present a minimally invasive aortic valve replacement performed through a right transaxillary minithoracotomy. This approach uses a single 4–5 cm lateral incision, minimizing chest wall trauma while providing excellent cosmetic results. It redefines surgical perspective by offering a direct, non-mediated view of the aortic valve with a naturally perpendicular trajectory to the annular plane. This results in optimal eye–hand alignment, shorter working distance and enhanced operative control, simplifying the procedure, not only compared to endoscopic or robotic techniques, but also to right anterior minithoracotomy, where direct vision is obtained through a less favourable trajectory and a more limited anterior intercostal space. The procedure is performed using standard instruments and standardized set-up, without the need for specialized or expensive technologies, improving reproducibility and scalability. Its intrinsic simplicity makes it particularly suited for fast-track protocols, facilitating on-table extubation and early mobilization. The combination with rapid-deployment valves further streamlines the operation by reducing cardiopulmonary bypass and cross-clamp times, while the transaxillary exposure ensures accurate annular alignment and controlled, symmetrical deployment. In this case, the patient was extubated on-table and discharged home after 5 days, illustrating how this approach can simplify minimally invasive aortic valve surgery while maintaining safety and precision.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart Valve Prosthesis ImplantationAortic ValveThoracotomyHeart Valve ProsthesisMinimally Invasive Surgical ProceduresAortic Valve StenosisHumansAxilla

Stichwörter der Autor:innen

Adult patientAortic valveAortic valve diseaseAortic valve replacementBioprostheticRight minithoracotomySutureless aortic valve prosthesis

Autor:innen und Institutionen

  • Cardiac Surgery Department, Lancisi Cardiovascular Center – OORR, Minimally Invasive and Trans Catheter Cardiac Surgery Research Center, Polytechnic University of Marche, Ancona, Italy

Zitieren

APA

Galeazzi, M., Mali, E., D'Alessio, S., Giusti, M., Zingaro, C., Malvindi, P., Berretta, P., & Di Eusanio, M. (2026). Transaxillary direct-view aortic valve replacement with Intuity Elite rapid-deployment valve. Multimedia Manual of Cardio-Thoracic Surgery. https://doi.org/10.1510/mmcts.2026.101

Vancouver

Galeazzi M, Mali E, D'Alessio S, Giusti M, Zingaro C, Malvindi P, et al. Transaxillary direct-view aortic valve replacement with Intuity Elite rapid-deployment valve. Multimedia Manual of Cardio-Thoracic Surgery. 2026. doi:10.1510/mmcts.2026.101

BibTeX
@article{Galeazzi2026,
  author = {Galeazzi, Michele and Mali, Erlil and D'Alessio, Simone and Giusti, Martina and Zingaro, Carlo and Malvindi, Pietro and Berretta, Paolo and Di Eusanio, Marco},
  title = {Transaxillary direct-view aortic valve replacement with Intuity Elite rapid-deployment valve},
  journal = {Multimedia Manual of Cardio-Thoracic Surgery},
  year = {2026},
  doi = {10.1510/mmcts.2026.101}
}
Kostenlos starten →