EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Test–retest reliability and minimal detectable change of pulse wave velocity and flow‐mediated dilation in paretic and non‐paretic limbs of older adults post‐stroke

Juliano A Abreu, Natalie D'Isabella, Derek W Stouth, Maureen J MacDonald iD, Ada Tang, Kevin Moncion iD

Physiological Reports · 2026

DOI: 10.14814/phy2.71138 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physiological Reports, 2026. Verfasst von Juliano A Abreu und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Rehabilitation Sciences, Faculty of Health Sciences, McMaster University, Hamilton, Ontario, Canada. Hauptthemen laut MEDLINE: Stroke, Pulse Wave Analysis, Vasodilation, Paresis. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Gouvernement du Canada | Canadian Institutes of Health Research (IRSC), Canadian Institutes of Health Research.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Arterial stiffness and endothelial dysfunction are non‐traditional risk markers after stroke, yet reliability and minimal detectable change (MDC) of pulse wave velocity (PWV) and flow‐mediated dilation (FMD) have not been established. We examined test–retest reliability and MDC of carotid‐femoral (cfPWV), carotid‐radial (crPWV), and femoral‐dorsalis pedis PWV (ffPWV), and absolute and relative brachial artery FMD in people >12 months post‐stroke. Seventeen individuals ( n = 4 (24%) females; 63.9 ± 8.6 years; 4.5 ± 2.8 years post‐stroke) completed two bilateral assessments of PWV via applanation tonometry and FMD via duplex ultrasound within 1 week. Intraclass correlation coefficients (ICC 2,1 ) were calculated via two‐way random‐effects models, and MDC derived at 68%, 90%, and 95% confidence levels. We found good‐to‐excellent reliability for cfPWV in paretic (ICC 2,1 = 0.85; 95% CI:0.59, 0.95) and non‐paretic (ICC 2,1 = 0.94; 95% CI:0.82, 0.98) limbs, with MDC 95% values of 2.23 and 1.68 m/s, respectively. crPWV and ffPWV exhibited poor reliability bilaterally (ICC 2,1 = 0.12–0.33). Relative FMD showed moderate reliability for paretic (ICC 2,1 = 0.50; 95% CI: −0.20, 0.85) and non‐paretic (ICC = 0.59; 95% CI:0.04, 0.84) limbs, with MDC 95% values of 6.88% and 7.65%, respectively. Reliability for absolute FMD was poor (ICC 2,1 = 0.11–0.44). These findings support cfPWV as a reliable vascular assessment in individuals >12 months post‐stroke, and provide stroke‐specific MDC values to guide interpretability in future trials.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

StrokePulse Wave AnalysisVasodilationParesisHumansFemaleReproducibility of ResultsMiddle AgedMaleAgedBrachial ArteryVascular StiffnessBlood Flow Velocity

Stichwörter der Autor:innen

endotheliumpulse wave analysisreliabilitystroke

Autor:innen und Institutionen

  • School of Rehabilitation Sciences, Faculty of Health Sciences, McMaster University, Hamilton, Ontario, Canada.
  • St. John's Rehab, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada.
  • Medicine, the Research Institute of St. Joe's, Hamilton, Ontario, Canada.
  • Department of Kinesiology, Faculty of Science, McMaster University, Hamilton, Ontario, Canada.
  • School of Physical & Occupational Therapy, Faculty of Medicine, McGill University, Montreal, Canada.

ORCID-Profile: Maureen J MacDonald, Kevin Moncion

Förderung

  • Gouvernement du Canada | Canadian Institutes of Health Research (IRSC)
  • Canadian Institutes of Health Research

Zitieren

APA

Abreu, J. A., D'Isabella, N., Stouth, D. W., MacDonald, M. J., Tang, A., & Moncion, K. (2026). Test–retest reliability and minimal detectable change of pulse wave velocity and flow‐mediated dilation in paretic and non‐paretic limbs of older adults post‐stroke. Physiological Reports. https://doi.org/10.14814/phy2.71138

Vancouver

Abreu JA, D'Isabella N, Stouth DW, MacDonald MJ, Tang A, Moncion K. Test–retest reliability and minimal detectable change of pulse wave velocity and flow‐mediated dilation in paretic and non‐paretic limbs of older adults post‐stroke. Physiological Reports. 2026. doi:10.14814/phy2.71138

BibTeX
@article{Abreu2026,
  author = {Abreu, Juliano A and D'Isabella, Natalie and Stouth, Derek W and MacDonald, Maureen J and Tang, Ada and Moncion, Kevin},
  title = {Test–retest reliability and minimal detectable change of pulse wave velocity and flow‐mediated dilation in paretic and non‐paretic limbs of older adults post‐stroke},
  journal = {Physiological Reports},
  year = {2026},
  doi = {10.14814/phy2.71138}
}
Kostenlos starten →