Cardiac timing modulates the contribution of compliance to effective arterial elastance
Physiological Reports · 2026-10 · 14 (19)
DOI: 10.14814/phy2.71112 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physiological Reports, online erschienen am 29.09.2026. Verfasst von Thomas Murchie. Beteiligte Einrichtung: Te Puna Wai Ora, Southern Critical Care, Dunedin Hospital, Dunedin, New Zealand. Hauptthemen laut MEDLINE: Arteries, Models, Cardiovascular, Heart. Die Arbeit nennt 13 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Effective arterial elastance ( E a ) is a lumped descriptor of arterial load. The contributions of arterial characteristics to E a , and their interactions with cardiac timing parameters, have not been fully elaborated. Previous studies have shown that E a can be approximated by equations of the form E a ≈ R / T + k / C , where R is either total or peripheral resistance, T is cardiac cycle time, and C is arterial compliance, but reported values for the coefficient k vary substantially, and some analyses suggest that compliance contributes little to E a . Here, an analytical approximation is derived from Sunagawa's Windkessel expression for E a by replacing the exponential term with a truncated Taylor expansion. The resulting approximation predicts that k is not constant but varies with cardiac timing, such that k ≈ 0.5 ( t d / T ) 2 , where t d is diastolic time. Approximation accuracy was assessed across 693 combinations of resistance, compliance, and heart rate and in a virtual population of 4374 adults derived from a published one‐dimensional vascular model. The linear approximation for E a closely tracked the Windkessel expression across the full parameter space ( R 2 > 0.9999, mean absolute percentage error 0.51%). In the virtual population, the approximation showed good agreement with the E surrogate P ES /SV (end‐systolic pressure/stroke volume), surpassing previous approximations. These findings show that the contribution of compliance to E a is modulated by cardiac timing and provide a mechanistic explanation for previously reported values of k .
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Te Puna Wai Ora, Southern Critical Care, Dunedin Hospital, Dunedin, New Zealand.
ORCID-Profile: Thomas Murchie
Zitieren
APA
Murchie, T. (2026). Cardiac timing modulates the contribution of compliance to effective arterial elastance. Physiological Reports, 14(19). https://doi.org/10.14814/phy2.71112
Vancouver
Murchie T. Cardiac timing modulates the contribution of compliance to effective arterial elastance. Physiological Reports. 2026;14(19). doi:10.14814/phy2.71112
BibTeX
@article{Murchie2026,
author = {Murchie, Thomas},
title = {Cardiac timing modulates the contribution of compliance to effective arterial elastance},
journal = {Physiological Reports},
year = {2026},
volume = {14},
number = {19},
doi = {10.14814/phy2.71112}
}
EUVIMED