Reliability of popliteal artery flow‐mediated dilation in the seated position
Physiological Reports · 2025
DOI: 10.14814/phy2.70252 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physiological Reports, 2025. Verfasst von Taskina Akhter und 3 weiteren Autor:innen. Beteiligte Einrichtung: Old Dominion University, Norfolk, Virginia, USA. Hauptthemen laut MEDLINE: Popliteal Artery, Sitting Position, Vasodilation. Die Arbeit nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Flow‐mediated dilation (FMD), a noninvasive measure of endothelial function, is commonly measured in the popliteal artery in the supine and upright body positions. However, reliability studies of the measurement in these positions are not well studied. This study aimed to examine the trial‐retrial and visit‐to‐visit reliability of popliteal artery FMD in the seated position. Popliteal artery FMD was measured in 20 healthy adults across two visits in the seated and prone positions to assess visit‐to‐visit reliability. Two measurements were taken for each body position at each visit to assess trial‐retrial reliability. %FMD was calculated as the percent change from baseline diameter to peak diameter. The reliability of FMD was assessed via the intraclass correlation coefficient (ICC). Popliteal artery %FMD shows moderate‐to‐good reliability in the seated position (ICC: 0.67–0.89) and poor‐to‐moderate reliability in the prone position (ICC: 0.25–0.74) within and between visits. There were no significant differences in baseline diameter or minimum diameter between body positions, visits, or trials ( p > 0.05). %FMD and peak diameter following cuff deflation demonstrated no significant difference between body positions ( p > 0.05). Popliteal artery FMD demonstrates good reliability in the seated position, supporting the development of a standardized measurement protocol.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Old Dominion University, Norfolk, Virginia, USA.
ORCID-Profile: Leryn J Reynolds
Zitieren
APA
Akhter, T., Wilson, P. B., Branch, J. D., & Reynolds, L. J. (2025). Reliability of popliteal artery flow‐mediated dilation in the seated position. Physiological Reports. https://doi.org/10.14814/phy2.70252
Vancouver
Akhter T, Wilson PB, Branch JD, Reynolds LJ. Reliability of popliteal artery flow‐mediated dilation in the seated position. Physiological Reports. 2025. doi:10.14814/phy2.70252
BibTeX
@article{Akhter2025,
author = {Akhter, Taskina and Wilson, Patrick B and Branch, J David and Reynolds, Leryn J},
title = {Reliability of popliteal artery flow‐mediated dilation in the seated position},
journal = {Physiological Reports},
year = {2025},
doi = {10.14814/phy2.70252}
}
EUVIMED