Exercise‐induced bronchoconstriction assessed by a ratio of surface diaphragm EMG to tidal volume
Physiological Reports · 2023
DOI: 10.14814/phy2.15860 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physiological Reports, 2023. Verfasst von Lishuang Wang und 5 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Respiratory Disease, Guangzhou Medical University, Guangzhou, China. Hauptthemen laut MEDLINE: Bronchoconstriction, Asthma, Exercise-Induced. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Guangzhou Municipal Science and Technology Bureau, Zhongnanshan Medical Foundation of Guangdong Province, Guangdong Science and Technology Program, Independent Project of State Key Laboratory of Respiratory Disease.
Abstract (Originalsprache)
Exercise‐induced bronchoconstriction (EIB) is usually assessed by changes in forced expiratory volume in 1 s (FEV 1 ) which is effort dependent. The purpose of this study was to determine whether the diaphragm electromyogram (EMG di ) recorded from chest wall surface electrodes could be used to reflect changes in airway resistance during an exercise challenge test and to distinguish patients with EIB from those without EIB. Ninety participants with or without asthma history were included in the study. FEV 1 was recorded before and 5, 10, 15, and 20 min after exercise. EIB was defined as an FEV 1 decline greater than 10% after exercise. A ratio of root mean square of EMG di to tidal volume (EMG di / V T ) was used to assess changes in airway resistance. Based on changes in FEV 1 , 25 of 90 participants exhibited EIB; the remainder were defined as non‐EIB participants. EMG di / V T in EIB increased by 124% (19%–478%) which was significantly higher than that of 21% (−39% to 134%) in non‐EIB participants ( p < 0.001). At the optimal cutoff point (54% in EMG di / V T ), the area under the ROC curve (AUC) for detection of a positive test was 0.92 ( p < 0.001) with sensitivity 92% and specificity 88%. EMG di / V T can be used to assess changes in airway resistance after exercise and could be used to distinguish participants with EIB from those without EIB.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- State Key Laboratory of Respiratory Disease, Guangzhou Medical University, Guangzhou, China.
- Division of Sleep and Circadian Disorders, Brigham and Women's Hospital and Harvard Medical School, Boston, Massachusetts, USA.
- College of Medicine and Public Health, Adelaide Institute for Sleep Health, Flinders University, Adelaide, South Australia, Australia.
ORCID-Profile: Lishuang Wang
Förderung
- Guangzhou Municipal Science and Technology Bureau, Zhongnanshan Medical Foundation of Guangdong Province
- Guangdong Science and Technology Program
- Independent Project of State Key Laboratory of Respiratory Disease
- National Nature Science Foundation of China
- Zhongnanshan Medical Foundation of Guangdong Province
- Science and Technology Planning Project of Guangdong Province
Zitieren
APA
Wang, L., Wu, S., He, B., Liu, S., Liang, S., & Luo, Y. (2023). Exercise‐induced bronchoconstriction assessed by a ratio of surface diaphragm EMG to tidal volume. Physiological Reports. https://doi.org/10.14814/phy2.15860
Vancouver
Wang L, Wu S, He B, Liu S, Liang S, Luo Y. Exercise‐induced bronchoconstriction assessed by a ratio of surface diaphragm EMG to tidal volume. Physiological Reports. 2023. doi:10.14814/phy2.15860
BibTeX
@article{Wang2023,
author = {Wang, Lishuang and Wu, Senrui and He, Baiting and Liu, Simin and Liang, Shanfeng and Luo, Yuanming},
title = {Exercise‐induced bronchoconstriction assessed by a ratio of surface diaphragm EMG to tidal volume},
journal = {Physiological Reports},
year = {2023},
doi = {10.14814/phy2.15860}
}
EUVIMED