Comparison of the Kron technique and digital manometry for measuring intra-abdominal pressure in emergency department patients diagnosed with ileus
Turkish Journal of Trauma and Emergency Surgery · 2024
DOI: 10.14744/tjtes.2024.36687 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Turkish Journal of Trauma and Emergency Surgery, 2024. Verfasst von Merve Unutmaz und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Emergency Medicine, Ankara Bilkent City Hospital, Ankara-Türkiye. Hauptthemen laut MEDLINE: Emergency Service, Hospital, Manometry, Ileus, Pressure. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
BACKGROUND: Numerous measurement techniques for intra-abdominal pressure have been explored, with the Kron Technique established as the gold standard. Despite its prominence, the search for alternative methods persists due to its lengthy application time, the requirement for additional equipment, and overall impracticality. This study investigated a quicker, more accessible method for effective intra-abdominal pressure measurement in the emergency department. It aimed to compare intra-abdominal pressure measurements in patients diagnosed with ileus using a digital manometer and the Kron Technique. METHODS: Conducted from October 2022 to February 2023, this single-center, prospective, single-blind method comparison study involved patients diagnosed with ileus at a tertiary emergency department. Intra-abdominal pressure was measured using both the Kron Technique and a digital manometer by separate practitioners blinded to the study results. RESULTS: The study included 30 patients. No statistically significant difference was observed in the intra-abdominal pressure measurements between the two methods (p
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Emergency Medicine, Ankara Bilkent City Hospital, Ankara-Türkiye.
- Department of Emergency Medicine, Ankara Yıldırım Beyazıt University, School of Medicine, Ankara-Türkiye.
- Department of Oncologic Surgery, Ankara Etlik City Hospital, Ankara-Türkiye.
Zitieren
APA
Unutmaz, M., Yıldırım, Ç., Unutmaz, M. E., Pamukçu Günaydın, G., Şener, A., & Gökhan, Ş. (2024). Comparison of the Kron technique and digital manometry for measuring intra-abdominal pressure in emergency department patients diagnosed with ileus. Turkish Journal of Trauma and Emergency Surgery. https://doi.org/10.14744/tjtes.2024.36687
Vancouver
Unutmaz M, Yıldırım Ç, Unutmaz ME, Pamukçu Günaydın G, Şener A, Gökhan Ş. Comparison of the Kron technique and digital manometry for measuring intra-abdominal pressure in emergency department patients diagnosed with ileus. Turkish Journal of Trauma and Emergency Surgery. 2024. doi:10.14744/tjtes.2024.36687
BibTeX
@article{Unutmaz2024,
author = {Unutmaz, Merve and Yıldırım, Çağdaş and Unutmaz, Mehmet Emin and Pamukçu Günaydın, Gül and Şener, Alp and Gökhan, Şervan},
title = {Comparison of the Kron technique and digital manometry for measuring intra-abdominal pressure in emergency department patients diagnosed with ileus},
journal = {Turkish Journal of Trauma and Emergency Surgery},
year = {2024},
doi = {10.14744/tjtes.2024.36687}
}
EUVIMED