EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY-NC 4.0

Influence of Thermal Pretreatments on the Cyclic Fatigue Resistance of Novel Reciprocating Nickel-Titanium Files: A Comparison of Low- and High-Temperature Modified Systems

Christoph Matthias Schoppmeier, Li Sun, Malin Janson, Florian Konstantin Wittich, Anna Greta Barbe

European Endodontic Journal · 16.07.2025 · 10 (4) · 333-342

DOI: 10.14744/eej.2025.95866 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift European Endodontic Journal, online erschienen am 16.07.2025. Verfasst von Christoph Matthias Schoppmeier und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Operative Dentistry and Periodontology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Cologne, Germany. Hauptthemen laut MEDLINE: Titanium, Nickel, Root Canal Preparation, Dental Instruments. Die Arbeit wurde bisher 4-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The flexibility and fracture resistance of nickel-titanium (NiTi) files have revolutionised root canal preparation—but file fractures caused by cyclic fatigue or torsional failure are challenging. Thermal pretreatments aim to improve fatigue resistance. This study compared the cyclic fatigue resistance (CFR) of four novel reciprocating NiTi file systems with low- versus high-temperature thermal modification under simulated clinical conditions.

Methods

Four systems (n=50) were investigated in vitro: low heat (LH; EdgeOne R-Utopia (Edge Endo, Albuquerque, New Mexico, USA); Procodile Q (Komet Dental, Lemgo, Germany)) and high heat (HH; Reciproc Blue (VDW GmbH, Munich, Germany); CC One Blue (Bondent, San Clemente, California, USA)). CFR was tested under simulated conditions (35±1°C). Two canal configurations were used: a single-curvature canal (60°, 5 mm radius, curvature centre 6 mm from the tip) and a double-curvature canal (additional 70°, 2 mm radius, curvature centre 2 mm from the tip). The files were tested in a ‘pecking’ motion (3 mm stroke, 0.5 Hz) until fracture occurred. The time to fracture (TTF), number of cycles to fracture (NCF) and fragment length (FL) were measured. Weibull analysis was performed to assess reliability and predict fracture behavior. Fracture fragments were analysed using scanning electron microscopy (SEM). Two-factor ANOVA was performed using instrument type and canal configuration as independent variables for each outcome measure (TTF, NCF, FL). Post hoc comparisons were conducted using Tukey-HSD (α = 0.05). Normal distribution was confirmed using Shapiro-Wilk testing.

Results

Differences in CFR were not significant between LH and HH systems (p=0.203), but were between file systems (p

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TitaniumNickelRoot Canal PreparationDental InstrumentsMaterials TestingHot TemperatureEquipment FailureHumansEquipment DesignStress, MechanicalDental Stress AnalysisTemperature

Substanzen

TitaniumNickeltitanium nickelide

Autor:innen und Institutionen

  • Department of Operative Dentistry and Periodontology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Cologne, Germany.
  • Department of Prosthetic Dentistry, University of Cologne, Faculty of Medicine and University Hospital Cologne, Cologne, Germany.

Zitieren

APA

Schoppmeier, C. M., Sun, L., Janson, M., Wittich, F. K., & Barbe, A. G. (2025). Influence of Thermal Pretreatments on the Cyclic Fatigue Resistance of Novel Reciprocating Nickel-Titanium Files: A Comparison of Low- and High-Temperature Modified Systems. European Endodontic Journal, 10(4), 333-342. https://doi.org/10.14744/eej.2025.95866

Vancouver

Schoppmeier CM, Sun L, Janson M, Wittich FK, Barbe AG. Influence of Thermal Pretreatments on the Cyclic Fatigue Resistance of Novel Reciprocating Nickel-Titanium Files: A Comparison of Low- and High-Temperature Modified Systems. European Endodontic Journal. 2025;10(4):333-342. doi:10.14744/eej.2025.95866

BibTeX
@article{Schoppmeier2025,
  author = {Schoppmeier, Christoph Matthias and Sun, Li and Janson, Malin and Wittich, Florian Konstantin and Barbe, Anna Greta},
  title = {Influence of Thermal Pretreatments on the Cyclic Fatigue Resistance of Novel Reciprocating Nickel-Titanium Files: A Comparison of Low- and High-Temperature Modified Systems},
  journal = {European Endodontic Journal},
  year = {2025},
  volume = {10},
  number = {4},
  pages = {333--342},
  doi = {10.14744/eej.2025.95866}
}
Kostenlos starten →